background image

WIL-19130-E-03  

WILDEN PUMP & ENGINEERING, LLC

P A R T S   L I S T I N G

Part Description

Pump Type

Part No.

Assy, Air Valve, P1/P2, PCMI

P1 & P2

01-2011-13

End Cap, P1/P2, PCMI

P1 & P2

01-2333-13

Assy, Air Valve, P1/P2, PCMI

P1 & P2

01-2011-20

End Cap, P1/P2, PCMI

P1 & P2

01-2333-20

ASSY, AIR VALVE, PX1, PCMI

PX1

01-2031-01

ASSY, AIR VALVE, PX2, PCMI

PX2

02-2031-01

End Cap, PX1/PX2, PCMI

PX1 & PX2

01-2343-01

Assy, Air Valve, P4/P8, PCMI

P4 & P8

04-2011-13

End Cap, P4/P8, PCMI

P4 & P8

04-2333-13

Assy, Air Valve, P4/P8, PCMI

P4 & P8

04-2011-20

End Cap, P4/P8, PCMI

P4 & P8

04-2333-20

Assy, Air Valve, P15, PCMI

P15

15-2011-20

End Cap, P15, PCMI

P15

15-2333-20

Assy, Air Valve, PV4-PV15,PCMI

PV4, PV8, PV15, PX4, PX8 & PX15

04-2031-01

End Cap, PV4/PX4, PCMI

PV4, PV8, PV15, PX4, PX8 & PX15

04-2343-01

ASSY, AIR VALVE, PV4-PV15,PCMI

PV4, PV8, PV15, PX4, PX8 & PX15

04-2031-03

End Cap, PV4/PX4, PCMI

PV4, PV8, PV15, PX4, PX8 & PX15

04-2343-03

ASSY, AIR VALVE, PX4-15, PCMI

PX4, PX8 & PX15

08-2031-20

End Cap, P4/P8, PCMI

PX4, PX8 & PX15

04-2333-20

ASSY, AIR VALVE, PS 4-15, PCMI

PS4, PS8 & PS15

04-2038-01

End Cap, PV/PX4, PCM I

PX4, PX8 & PX15

04-2343-01

ASSY, AIR VALVE, PS4, ANO PCMI

PS4, PS8 & PS15

04-2038-11

End Cap, PV/PX4, PCM I

PS4, PS8 & PS15

04-2343-01

Set Screw, Shcp, 1/4”-20

ALL but P15

99-6340-08

Set Screw, Shcp, 7/16”-14

P15

99-6341-08

PCMI Counter

ALL

99-8150-99

Magnet, Round, Ndfeb, .200

All but P15

99-8320-99

Magnet, Round, Ndfeb, .375

P15

99-8321-99

Sensor W/ 36” Leads

ALL

99-8330-99

Summary of Contents for Wilden PCMI

Page 1: ...wildenpump com EOM Engineering Operation Maintenance PCM I Pump Cycle Monitor Where Innovation Flows WIL 19130 E 03 REPLACES WIL 19130 E 02 ...

Page 2: ...et of the pump to ensure proper operation CAUTION Penetrating the PCMI enclosure for mount ing purposes or to install additional wiring will negate the NEMA 4X enclosure rating PCMI The PCMI counts pump cycles by sensing the pres ence of the Pro Flo Pro Flo X and Pro Flo SHIFT air valve spool The sensor located at the air valve end cap detects the presence of a magnet located at the end of the air...

Page 3: ...P15 PCMI P15 15 2333 20 Assy Air Valve PV4 PV15 PCMI PV4 PV8 PV15 PX4 PX8 PX15 04 2031 01 End Cap PV4 PX4 PCMI PV4 PV8 PV15 PX4 PX8 PX15 04 2343 01 ASSY AIR VALVE PV4 PV15 PCMI PV4 PV8 PV15 PX4 PX8 PX15 04 2031 03 End Cap PV4 PX4 PCMI PV4 PV8 PV15 PX4 PX8 PX15 04 2343 03 ASSY AIR VALVE PX4 15 PCMI PX4 PX8 PX15 08 2031 20 End Cap P4 P8 PCMI PX4 PX8 PX15 04 2333 20 ASSY AIR VALVE PS 4 15 PCMI PS4 PS...

Page 4: ...MI Air Valve Spool Set Screw End Cap Sensor Magnet Control Module 3 RST EN 1 COM 5 RST LS 4 HS 6 LS at the back of the LCD display The wiring can be extended up to 250 feet for ease of installation To enable the front panel reset button simply connect a wire between terminals 1 COM and 3 RST EN A momentary switch can be connected to terminals 1 COM and 5 RST for remote reset Pump is running but th...

Page 5: ...N O T E S ...

Page 6: ...N O T E S ...

Page 7: ...Prior approval must be obtained from Wilden for return of any items for warranty consideration and must be accompanied by the appropriate MSDS for the product s involved A Return Goods Tag obtained from an authorized Wilden distributor must be included with the items which must be shipped freight prepaid The foregoing warranty is exclusive and in lieu of all other warranties expressed or implied w...

Page 8: ...nformation and illustrations contained in this document without prior notice This is a non contractual document 03 2015 Authorized PSG Representative Where Innovation Flows PSG 22069 Van Buren St Grand Terrace CA 92313 5607 P 1 909 422 1731 F 1 909 783 3440 wildenpump com Copyright 2015 PSG aDovercompany WIL 19130 E 03 REPLACES WIL 19130 E 02 ...

Reviews: