background image

WILDEN PUMP & ENGINEERING, LLC 

WIL-19130-E-03

  Pump Cycle Monitor

CAUTION:

 Before any maintenance or repair is 

attempted, the compressed air line to the pump 

should be disconnected and all air pressure allowed 

to bleed from pump. 

WARNING:

 Do not recharge, disassemble, crush or 

expose lithium power cell to temperatures above 

100°C (212°F). 

CAUTION:

 When removing the end cap using 

compressed air, the air valve end cap may come out 

with considerable force.  Hand protection such as a 

padded glove or rag should be used to capture the 

end cap.

CAUTION:

 Use caution when mounting the PCMI 

enclosure in areas where wash down occurs.

NOTE:

 The PCMI is to be used with Wilden sensor and 

embedded air valve spool magnet ONLY.

CAUTION:

 When adding a remote resetting switch, 

ensure that 24-gauge wire or larger is used and that 

the remote switch is mounted within 250 feet of the 

PCMI.  

CAUTION:

 The PCMI enclosure must be mounted 

within 250 feet of the pump to ensure proper 

operation.

CAUTION:

 Penetrating the PCMI enclosure for mount-

ing purposes or to install additional wiring will negate 

the NEMA 4X enclosure rating.

PCM

I

 

The PCMI counts pump cycles by sensing the pres-

ence of the Pro-Flo

®

, Pro-Flo X

 and Pro-Flo

®

 SHIFT 

air valve spool.  The sensor, located at the air valve 

end cap, detects the presence of a magnet located at 

the end of the air valve spool.  The PCMI unit registers 

a complete pump cycle when the spool shifts away 

from the sensor and subsequently returns to the origi-

nal position.  The counter resets itself to zero automat-

ically after reaching 100 million cycles.  The PCMI has 

a reset switch located on the face of the PCMI module 

that can be activated to allow “on the spot” resetting 

of the counter or disabled to prevent inadvertent loss 

of data.  The unit also has the ability to be reset from 

a remote location.

H O W   I T   W O R K S

C A U T I O N S

R E A D   F I R S T

LW0224, REV A

D I M E N S I O N A L   D R A W I N G

DIMENSIONS – PCMI

ITEM

METRIC (mm)

STANDARD (inch)

A

86

3.4

B

61

2.4

C

104

4.1

D

117

4.6

E

135

5.3

F

61

2.4

G

43

1.7

H

25

1.0

J

5 DIA.

0.2 DIA.

Summary of Contents for Wilden PCMI

Page 1: ...wildenpump com EOM Engineering Operation Maintenance PCM I Pump Cycle Monitor Where Innovation Flows WIL 19130 E 03 REPLACES WIL 19130 E 02 ...

Page 2: ...et of the pump to ensure proper operation CAUTION Penetrating the PCMI enclosure for mount ing purposes or to install additional wiring will negate the NEMA 4X enclosure rating PCMI The PCMI counts pump cycles by sensing the pres ence of the Pro Flo Pro Flo X and Pro Flo SHIFT air valve spool The sensor located at the air valve end cap detects the presence of a magnet located at the end of the air...

Page 3: ...P15 PCMI P15 15 2333 20 Assy Air Valve PV4 PV15 PCMI PV4 PV8 PV15 PX4 PX8 PX15 04 2031 01 End Cap PV4 PX4 PCMI PV4 PV8 PV15 PX4 PX8 PX15 04 2343 01 ASSY AIR VALVE PV4 PV15 PCMI PV4 PV8 PV15 PX4 PX8 PX15 04 2031 03 End Cap PV4 PX4 PCMI PV4 PV8 PV15 PX4 PX8 PX15 04 2343 03 ASSY AIR VALVE PX4 15 PCMI PX4 PX8 PX15 08 2031 20 End Cap P4 P8 PCMI PX4 PX8 PX15 04 2333 20 ASSY AIR VALVE PS 4 15 PCMI PS4 PS...

Page 4: ...MI Air Valve Spool Set Screw End Cap Sensor Magnet Control Module 3 RST EN 1 COM 5 RST LS 4 HS 6 LS at the back of the LCD display The wiring can be extended up to 250 feet for ease of installation To enable the front panel reset button simply connect a wire between terminals 1 COM and 3 RST EN A momentary switch can be connected to terminals 1 COM and 5 RST for remote reset Pump is running but th...

Page 5: ...N O T E S ...

Page 6: ...N O T E S ...

Page 7: ...Prior approval must be obtained from Wilden for return of any items for warranty consideration and must be accompanied by the appropriate MSDS for the product s involved A Return Goods Tag obtained from an authorized Wilden distributor must be included with the items which must be shipped freight prepaid The foregoing warranty is exclusive and in lieu of all other warranties expressed or implied w...

Page 8: ...nformation and illustrations contained in this document without prior notice This is a non contractual document 03 2015 Authorized PSG Representative Where Innovation Flows PSG 22069 Van Buren St Grand Terrace CA 92313 5607 P 1 909 422 1731 F 1 909 783 3440 wildenpump com Copyright 2015 PSG aDovercompany WIL 19130 E 03 REPLACES WIL 19130 E 02 ...

Reviews: