56
22.8. COMBUSTION AIR
See Section 9.11 - COMBUSTION AIR AND FRESH AIR INTAKE ADAPTER INSTALLATION (OPTIONAL)
22.9. ELECTRICAL WIRING
See Section 9.9 - ELECTRICAL CONNECTIONS
22.10. THERMOSTAT
See Section 10 - THERMOSTAT INSTALLATION
23. OPERATION INSTRUCTION
23.1. FAN SPEED CONTROL
See Section 11.5 - DISTRIBUTION BLOWER SPEED CONFIGURATION
23.2. COMBUSTION SAFETY CONTROL
The AFG type oil burner is equipped with an electronic control including a pre-purge function and a new, more durable
drive motor.
23.3. PRE-PURGE
When there is a call for heat, the burner’s fan will run for 15 seconds before the actual ignition takes place to vent the
combustion chamber and generate a proper draft. This will result in a smoother ignition of the oil burner.
23.4. SAFE OPERATION
If the flame goes out while the burner is running, the control will then switch to the "RECYCLE" mode and cut the fuel
supply to the burner for 60 seconds. After this delay, the control goes back to "IGNITION" mode. If the flame goes out
3 times in a row, the control will switch to the "LOCKOUT" mode to prevent a continuous cycling of the ignition process,
which would cause a premature soot-up of the combustion chamber and smoke pipe. To deactivate t
he “LOCKOUT”
mode, press and hold the reset button of the control for 30 seconds.
A green diagnostic light on the control has four states:
-
On = Flame present
-
Off = No flame
-
2 seconds On, 2 seconds Off = "Recycle" mode
-
1/2 second On, 1/2 second Off = "Lockout" mode TEMPORARY SHUT-OFF
23.5. TEMPORARY DISENGAGEMENT OF THE BURNER
By pressing and holding the reset button, the burner will shut-off until the reset button is released. When the button is
released, the control will start over at the beginning of the normal cycle.
FOR ADDITIONAL INFORMATIONS ON OPERATION SEQUENCES OF THE BURNER, CONSULT THE BURNER
INSTRUCTION MANUAL.
Summary of Contents for MAX CADDY PF01102
Page 10: ...10...
Page 47: ...47 15 GENERAL ELECTRICAL DIAGRAM...
Page 48: ...48 16 ELECTRICAL DIAGRAM FOR PARALLEL FURNACE...
Page 49: ...49 17 ELECTRICAL DIAGRAM FOR ELECTRIC UNIT...
Page 55: ...55 22 7 DIFFERENT INSTALLATION...
Page 61: ...61 26 ELECTRICAL DIAGRAM BECKETT OIL UNIT...
Page 62: ...62 27 ELECTRICAL DIAGRAM RIELLO OIL UNIT...
Page 64: ...64 28 4 24V ADDITIONNAL EQUIPMENT 28 5 AIR CONDITIONNING DAMPER 28 6 HUMIDIFIER...
Page 65: ...65 28 7 HEAT PUMP 29 EXPLODED VIEW AND PART LIST...
Page 66: ...66...
Page 67: ...67...
Page 68: ...68...
Page 69: ...69...
Page 70: ...70...
Page 71: ...71...
Page 72: ...72...