30
10. THERMOSTAT INSTALLATION
10.1. WOOD FURNACE ONLY
The furnace must be connected to a thermostat. You can use the one provided with the unit or use one that is already
installed in your home. The thermostat must be installed on an inside wall and located where it is not likely to be
affected by the draft coming from an air outlet. It must be installed at a minimum of 55 inches (140cm) above the floor.
It is recommended to connect the thermostat to the furnace with a seven or eight threads wire connecting terminals
Rc, Rh (connect only one of the two terminal R if there is a jumper between Rc and Rh in the thermostat), C, W, Y, G,
O and B. If the thermostat is using a dry contact (powered by batteries), it is not necessary to connect the C (common)
terminal to the thermostat. Refer to the electrical diagram.
Once wired to the furnace, it is possible to verify the signals coming from the wall thermostat. Simply go on the touch
screen
main menu, under the “TROUBLESHOOT LINK’’ menu and going to page 1 as shown below. When a signal is
sent from the thermostat, the circle corresponding to the signal should appear green.
10.1.1. COMBINATION WOOD-ELECTRIC OR WOOD-OIL FURNACE
Only one thermostat is necessary to control the wood furnace and any other auxiliary heating source. Installing the
thermostat is done the same way as if the furnace was wood only. See Section 11.4.1 - TRANSITION TO AN
AUXILIARY HEAT SOURCE to learn how to make it work.
10.1.2. COMBINATION WOOD-ELECTRIC-OIL
Only one thermostat is necessary to control the wood furnace and any other auxiliary heating source. Installing the
thermostat is done the same way as if the furnace was wood only. See Section 11.4.1 - TRANSITION TO AN
AUXILIARY HEAT SOURCE to learn how to make it work.
Summary of Contents for MAX CADDY PF01102
Page 10: ...10...
Page 47: ...47 15 GENERAL ELECTRICAL DIAGRAM...
Page 48: ...48 16 ELECTRICAL DIAGRAM FOR PARALLEL FURNACE...
Page 49: ...49 17 ELECTRICAL DIAGRAM FOR ELECTRIC UNIT...
Page 55: ...55 22 7 DIFFERENT INSTALLATION...
Page 61: ...61 26 ELECTRICAL DIAGRAM BECKETT OIL UNIT...
Page 62: ...62 27 ELECTRICAL DIAGRAM RIELLO OIL UNIT...
Page 64: ...64 28 4 24V ADDITIONNAL EQUIPMENT 28 5 AIR CONDITIONNING DAMPER 28 6 HUMIDIFIER...
Page 65: ...65 28 7 HEAT PUMP 29 EXPLODED VIEW AND PART LIST...
Page 66: ...66...
Page 67: ...67...
Page 68: ...68...
Page 69: ...69...
Page 70: ...70...
Page 71: ...71...
Page 72: ...72...