PSC XANTRA VV ADVANCED Installation And Operating Instructions Manual Download Page 6

SPECIFICATION OF PV CHARGE CONTROLLER 

 

communication  to  extend  the  communication  distance 

(optional function) 

 

New  SOC  method  indicates  the  power  generation 

information of daily, monthly and total. 

 

The  temperature  compensation  function  compensates  the 

voltage based on different temperature. 

 

It  adopts  graphical  dot-matrix  3’’  LCD  and  4  touching 

buttons as HMI for full menu and easy operation 

 

RTC function indicates the real time and temperature. 

3.

 

Installation Instruction 

3.1

 

Precautions 

Warning: do not install  it with open type lead-acid  battery in a 

confined  space,  also  do  not  install  it  in  a  sealed  place  where 

battery gas may be assembled. These will cause explosion. 

Warning: If the positive and negative of battery is short circuit, 

there will be explosion or fire, so be careful about it. 

Warning: The PV arrays may produce a high voltage which will 
shock to people, it’s very dangerous, so be careful about it when 

you install the system. 

Caution: When you wire the solar controller, please ensure there 

is  enough  air  through  the  heat  sink  of  controller,  we  suggest 

200mm space at each up and down. 

Caution:  Please  ensure  all  battery  and  PV  arrays  are  turn  off 

when you install the solar system. We suggest users to install a 

break  between  PV  arrays  and  controller,  also  same  between 

battery and controller. 

Caution:  our  solar  controller  is  equipped  with  corresponding 

cold pressing terminal for different current. Please tightly press 

it  with  wire.  Loose  connection  will  gather  heat  which  is  very 

dangerous.  Please  also  ensure  there  is  no  any  fur  between  the 

wire and cold pressing terminal. 

Caution:  Please  use  insulated  tools  and  avoid  placing  metal 

Summary of Contents for XANTRA VV ADVANCED

Page 1: ...123655444 Users Thank you very much for selecting our Solar Charge Controller This manual contains important information and suggestion about installation operation and trouble shooting Please read th...

Page 2: ...G INSTRUCTION 5 3 3MOUNTING 5 3 4WIRING THE CONTROLLER TO THE SYSTEM 5 4 OPERATION 6 4 1INSTRUCTION OF HMI INTERFACE 6 4 2THE INSTRUCTION OF THE LCD DISPLAY 7 4 3INSTRUCTION OF SUBMENU 8 4 4INSTRUCTIO...

Page 3: ...tempt to repair it without authority from manufacturer 1 2 3 Please avoid direct sunlight if you install it outdoor 1 2 4 Install external fuses breakers as required 1 2 5 Install the controller in we...

Page 4: ...s manual nor the conditions and methods of installation operation usage and maintenance of the system controller Improper installation of the system may result in damage to property and as a result to...

Page 5: ...ase also ensure that the permissible model specific rated currents and voltages are not exceeded No liability is accepted when the device is used in a manner other than for the intended purpose Handle...

Page 6: ...short circuit there will be explosion or fire so be careful about it Warning The PV arrays may produce a high voltage which will shock to people it s very dangerous so be careful about it when you ins...

Page 7: ...DC output positive pole and DC output negative pole the diagram as following Solar Panel Battery Load S S B B L L1 3 3 Mounting 3 3 1 Choose mounting location Mount the controller near to battery and...

Page 8: ...n cause severe shock or injury Be careful operation when installing solar wiring 3 4 3 Connect loads to the controller NOTE Right connect the positive and negative 3 4 4 Confirm the wiring Double chec...

Page 9: ...the LCD will display the following main screen Menu 1 4 2 1 The first line from left to right which in turn is equipment ID ambient temperature and total days the equipment runs 4 2 2 The second line...

Page 10: ...The last line from left to right which in turn is the real time and date 4 3 Instruction of submenu 4 3 1 In the main screen press menu key it will enter to the following interface Submenu 1 Monitori...

Page 11: ...nge The factory password is 1234 4 4 1 Device Set In the submenu 1 interface when the cursor in the 2 Device Set position press confirm key to the following interface Users can set the Equipment ID Da...

Page 12: ...if battery real voltage low than this value the controller will stop giving DC output UV_Rect Under voltage recovery when battery real voltage recovery to this value from under voltage the controller...

Page 13: ...onfirm key to the following interface 4 4 6 Factory Reset In the submenu 1 interface when the cursor in the 8 Factory Reset position press the confirm key to the following interface If user chooses th...

Page 14: ...ze charging point Constant current regulation is used to prevent heating and excessive battery gassing As to factory default setting the equalize charging stage will remain 120 minutes and then enter...

Page 15: ...e naked wires to make sure insulation is not damaged for serious sunshine frictional wear dryness insects or rats etc Maintain or replace the wires if necessary Check if LCD display Pay attention to a...

Page 16: ...No load loss 0 5W Equalize voltage 14 4V 28 8V 57 6V Adjustable Equalize recovery voltage 13 2V 26 4V 52 8V Equalize charging time 120 Minutes Float voltage 13 8V 27 6V 55 2V Under voltage disconnect...

Page 17: ...mes than rated system voltage Check if the solar power is high than the Max solar power which controller demands OV Temp High temperature The heat sink s temperature is very high The controller will s...

Page 18: ...troller doesn t charge when sun light on PV modules The PV modules short circle Check if the connections of PV modules is right and tightened Small charging current The sunshine is not good Battery is...