SPECIFICATION OF PV CHARGE CONTROLLER
16
Fault
Possible reason
Troubleshooting
It doesn’t work when you first
install it
Battery voltage is too low
Battery reverse connection
Change battery or charging battery by
other equipment
Please adjust the connection
The controller doesn’t charge
when sun light on PV modules
The PV modules short circle.
Check if the connections of PV
modules is right and tightened.
Small charging current
The sunshine is not good
Battery is close to full charge
Wait for good sunshine
It’s normal