Interface Related Features
3-14
PowerScan
®
7000 Linear Imager
RS-232 Interface Features — cont.
Hardware Flow Control
Disable Hardware Control —
The scanner transmits to the host regardless of
any activity on the CTS line.
Enable CTS Flow Control —
The CTS signal controls transmission of data
to the host.
Enable CTS Scan Control —
The CTS line must be active for the scanner to
read and transmit data. While the CTS line is inactive, the scanner
remains in a host-disabled state; following a successful label transmis-
sion, the CTS signal must transition to inactive and then to active to
enable scanning for the next label.
Intercharacter Delay
This delay is inserted after each data character transmitted. If the trans-
mission speed is too high, the system may not be able to receive all char-
acters. You may need to adjust the delay to make the system work
properly.
Software Flow Control
Disables/Enables software control using XON/XOFF characters.