If the laser beam is not centered, tap the detector area on the screen [
1
] to access the
XY View
.
Correct the alignment condition by shimming and moving the machines laterally following the bold
vertical [
2
] and horizontal [
3
] arrows. Machines should be moved to within acceptable tolerances
indicated by a happy smiley [
] or an OK icon [
] while observing shaft alignment best prac-
tices.
The system monitors both horizontal and vertical Live Move concurrently. If the vertical view (V) is
selected when the function Live Move function is started, only the vertical condition will be displayed
(although both planes are being monitored simultaneously). Likewise, if the horizontal view (H) is
selected, then only the horizontal condition will be displayed (but both planes monitored sim-
ultaneously).
After moving machines to within tolerance, tighten the foot bolts then tap
.
Tap
to remeasure and verify the Live Move results, and determine exact alignment condition.