Deleting the ring buffers
The storage concept of VIBGUARD IIoT is designed in such a way that the most up-to-date data is available even if
the measurement data is not backed up at regular intervals. Automatically generated measurement data can be sto-
red despite the memory being full. In addition, a ring buffer architecture is used which always replaces the oldest
measurement with the most recent measurement.
Therefore, manually measured data configured via a diagnostic group from the OMNITREND Center software
should always be transferred and stored on the PC for analysis if such data is to be retained. This data should then
be deleted from VIBGUARD IIoT in order to save memory space. This especially applies to time signals with lengthy
measurement times which take up a considerable amount of memory space.