PRULITE.COM 213.746.0360
Prudential Ltg. reserves the right to change design specifications or materials without notice. Please visit prulite.com for most current data.
© 2015 All rights reserved – All products manufactured at: Prudential Ltg. 1774 E. 21st Street, Los Angeles, CA 90058
WARNING:
Ground fixture in accordance with local and national electrical codes. Failure to do so may result in serious personal injury.
6
2 of
LED
Bionic
| Recessed Linear
4˝ Slot
I N S T A L L A T I O N I N S T R U C T I O N S
CO N T IN U O U S R U N X 3, X 7
I N S T A L L A T I O N
LENS
WALL RAIL
LENS REMOVAL TOOL
8-32_X_3_8_HWH_SELF_TAP
ADJUSTABLE HANGER BRACKETS
T-BAR BRACKETS
OVERHEAD MOUNTING BRACKET
ALIGNER SPLINES
“L” Trim
2)
1)
Install aligner splines on housing.
— 2 per joint on Seamless,
Flush and Reg1.
— 4 per joint on Reg3.
Secure fixture to structure with wire and all
thread. (Multiple options.)
Mounting Detail (1) Housing Detail for 1/4-20
℄
X
Y
Y
1/4˝ Wiring K.O.
MOUNTING CONVERSION CHART:
* From Centerline
X =
2’
3’
4’
5’
6’
7’
8’
Y =*
9˝
15˝
21˝
27˝
33˝
39˝
45˝
℄
LENS
WALL RAIL
LENS REMOVAL TOOL
8-32_X_3_8_HWH_SELF_TAP
ADJUSTABLE HANGER BRACKETS
T-BAR BRACKETS
OVERHEAD MOUNTING BRACKET
ALIGNER SPLINES
“L” Trim
3)
LENS
WALL RAIL
LENS REMOVAL TOOL
8-32_X_3_8_HWH_SELF_TAP
ADJUSTABLE HANGER BRACKETS
T-BAR BRACKETS
OVERHEAD MOUNTING BRACKET
ALIGNER SPLINES
“L” Trim
4)
If additional holes are drilled in top plate for 1/4-20 all thread,
support with additional #8 screws at closest locations to
new holes.
Fasten inside joiner brackets on row mounted housings.
8-32 x 3/8˝
Self-tapping Screws
8-32 x 1/4˝
Machine Screws
(BY OTHERS)
WARNING:
Failure to properly install top screws will void warranty
OPTION A.
Insert 1/4-20 all-thread. Can protrude
into housing no more than 3/8˝
OPTION B.
Hang 1/4-20 all-thread or wire from
adjustable hanger bracket
LENS
WALL RAIL
LENS REMOVAL TOOL
8-32_X_3_8_HWH_SELF_TAP
ADJUSTABLE HANGER BRACKETS
T-BAR BRACKETS
OVERHEAD MOUNTING BRACKET
ALIGNER SPLINES
“L” Trim
5)
Slide and tighten aligner splines over joints.
LENS
WALL RAIL
LENS REMOVAL TOOL
8-32_X_3_8_HWH_SELF_TAP
ADJUSTABLE HANGER BRACKETS
T-BAR BRACKETS
OVERHEAD MOUNTING BRACKET
ALIGNER SPLINES
“L” Trim
LENS
WALL RAIL
LENS REMOVAL TOOL
8-32_X_3_8_HWH_SELF_TAP
ADJUSTABLE HANGER BRACKETS
T-BAR BRACKETS
OVERHEAD MOUNTING BRACKET
ALIGNER SPLINES
“L” Trim
6)
7)
Measure and install
backer flanges (X7BF)
at appropriate height.
(Required for X7,
except on pre-
framed soffits.)
Install drywall and
self-tapping drywall
screws into X7BF.
Backer flange can
install with up to 21/8˝
thick hard ceiling
Drywall should be
flush with housing
Drywall screws (by others)
must be flush with drywall
Option to
hang drywall
from backer
flange
SHIPPING STRAPS
07-02-2020