5.3 Wiring Information 

 

5.3.1 Cable Color codes for Pig Tail Reader  

 

 

 

 

 

 

 

 

 

Red 

+VDC 12V (nominal) 

 

Black & White 

Ground 

        N,  

Green 

Wiegand Data 0 

 

White  

Wiegand Data 1 

 

Orange 

Green LED 

 

Yellow 

Buzzer 

 

Blue 

Hold 

 

Brown 

Red LED 

 

Grey 

RS485 - 

 

Pink 

RS485 + 

 

Violet 

Tamper Output 

 

Black / Drain 

Shield Ground  

 

 

 

 
 

 

** For Wiring diagrams and termination points please see your control panel user 
manual. Installations will differ between access control panel manufacturers.  

 

 

 

  

 

 

 

 

 

 

 

Caution: 

 

 

  

  

  

 

 

During Wiring make sure that the +VDC lines does not make contact with any other cables, as it might 
affect reader functionality/ cause damage to the reader.  

 

 

 

 

 

  

  

  

 

 

 

 

 

 

 

 

Summary of Contents for Mobile Reader Pro

Page 1: ...V 1 5 Proxy Technologies Inc User manual For Proxy Reader Pro Mullion Document number PRXY 1001UM Confidential...

Page 2: ...017 1 0 Initial Draft Andrew Tam 12 14 2017 1 1 Specs finalized Line Drawings updated Andrew Tam 01 28 2018 1 2 Updated Table 4 Andrew Tam 7 31 2018 1 3 Updated WEEE WiFi to IEEE 802 11 RF exp Andrew...

Page 3: ...7 4 1 Rated current at different operating voltages 7 4 1 1 Rated current for Model 8010 7 5 0 Installation details 8 5 1 Parts List 8 5 2 Recommended Infrastructure 8 5 3 Wiring Information 9 5 3 1...

Page 4: ...the control panel Standard HF LF BLE IEEE 802 11b g n The reader comes in one variant in functionality Standard HF LF BLE IEEE 802 11b g n 2 0 Reader 2 1 Functionality Proxy Reader Pro is a physical...

Page 5: ...User Manual v1 6 5 Printed copies of this document are uncontrolled 2 3 Proxy Reader Pro Mullion Wall Plate...

Page 6: ...x Communication protocol Wiegand RS485 2wire Half Duplex BLE IEEE 802 11b g n Credential Type RFID Standard 26 Bit BLE Default 32 Bit Transmission Technology WIEGAND OSDP OSDP2 Communication via Wiega...

Page 7: ...not provided by the Card Readers The Standby Power Level is dependent on the external power source connected to the Card Reader For RS485 use 24 AWG twisted pair cable with a shunt capacitance of 16...

Page 8: ...n anchor plugs 6 Size x 1 2 Nos 5 2 Recommended Infrastructure All cabling and wiring shall be UL Listed and or UL Recognized All readers shall be powered by UL listed power limited power supply or po...

Page 9: ...n LED Yellow Buzzer Blue Hold Brown Red LED Grey RS485 Pink RS485 Violet Tamper Output Black Drain Shield Ground For Wiring diagrams and termination points please see your control panel user manual In...

Page 10: ...on the wall as per the image above corresponding to the type of reader Insert the nylon screw plugs into the wall Connect the wires as per the Table in Section 5 3 1 Proxy Reader Mullion Wall Plate i...

Page 11: ...Proxy Logo Displayed 2 Present a card Access Granted The Indicator LED blinks green and a short Beep is emitted Access Denied Dependant on Access controller configuration 3 Present a Phone with Proxy...

Page 12: ...ment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful in...

Page 13: ...odifications not expressly approved by Proxy Technologies Inc could void the user s authority to operate the equipment 6 2 IC This Class B digital apparatus complies with Canadian ICES 003 This device...

Page 14: ...pre defined RF parameters Each product RF power level is measured to ensure the power level not exceeding the target power level in a fully calibrated setup The user has no possibility to change these...

Page 15: ...nt WEEE This symbol means that according to local laws and regulations your product and or its battery shall be disposed of separately from household waste When this product reaches its end of life ta...