19
))))))) (((((((
))))))) (((((((
Master
(repeating)
Figure 9
Repeating
Building to Building Configuration
Two Access Points can be used to connect LANs in separate buildings. Here are some
guidelines:
❑
The antennas should be placed so they are line of sight for best range. In many
cases, they will be placed on rooftops.
❑
One Access Point will be a Master; the other will be a Station. The two devices
must be on the same Domain and Security ID.
❑
Disable the Fixed Nodes Filter on both of the Access Points.
❑
On a Novell NetWare LAN, disable the IPX RIP Broadcast Packets Filter, the
IPX SAP Broadcast Packets Filter, and IPX LSP Broadcast Packets Filter.
Diagnostic tools are available in the RangeLAN2 752x Access Point. See Chapter 13.