background image

Proxel Engineering Ltd     ------------------------www.proxel-bg.com-----------------          -DTSF3+        v2.4 /2017 

„DTSF3+”   Temperature Controller For Solar Thermal And Heating 

Application With 8 Schemes

 

BRIEF DESCRIPTION 

 

The unit is a programmable digital temperatute controller for solar thermal and 

heating plants. It manages the interaction between the solar collector, hot water tank, 
storage tank, boiler, pumps, valves and electric heater. The unit helps to improve 
thermal comfort by combining high efficiency with autonomy of the system. The 
joint functional work of differential temperature, built-in clock and a flexible treshold temperatures 
further helps to increase energy savings. It has 8 pre-programmed functional diagrams which cover 
vast range of prooved by practice application. The application of the device extends from thermo-
syphonic solar water heaters to more complex solar systems with a combination of hot water tank 
and storage tank, boiler and heating. It also can control one HF pump with PWM input. 

 

Functional diagrams, schemes, sensors and outputs arrangement: 

 

Scheme 0

 – Thermosyphonic panel with integrated tank and trace heating 

 

Sensors                                

Schm=0; “TSyphTrH”

 

 

TS1 – trace temperature 

 

TS2 – solar tank temperature 

 

TS3 – not used;  

 

Level sensor - Terminals 3 and 4 

 

Outputs 

 

R1 – trace heater 

 

R2 – electric heater of solar operated tank 

 

R3 – refill valve (N.C.)

 

Level sensor: 

Controls electric valve for proper boiler fill up while monitoring the water level with submerged 

electrode.

 

 

Scheme 1-

 Thermosyphonic panel with integrated tank and recirculation; 

 

Sensors                               

Schm=1; “TSyphReC”

 

 

TS1 – temperature of suplimentary tank/recirculation point 

 

TS2 – solar tank temperature 

 

TS3 – trace temperature 

Outputs 

 

R1 – recirculation pump 

 

R2 – electric heater of solar operated tank 

 

R3 – * valve – not used 

 

Scheme

 2- Solar panel with one storage tank and electric heater (standard) 

 

Sensors

                                

Schm=2; „dT.EL+T1”

 

 

TS1 – temperature of solar panel 

 

TS2 – tank temperature at bottom (at coil position) 

 

TS3 – tank temperature at top (for heater control) 

Outputs 

 

R1 – solar pump 

 

R2 – electric heater of tank 

 

R3 – emergency draining valve 

 

Scheme

 2а - Solar panel with two storage tanks – Ta-with electric heater, Tb-with solar heating,  

 

Sensors

  

                       Schm=2; „dT.EL+T1”

 

 

TS1 – temperature of solar panel 

 

TS2 – temperature of electric heater operated tank 

 

TS3 – temperature of solar operated tank 

Outputs 

 

R1 – solar pump 

 

R2 – electric heater of tank 

 

R3 – emergency draining valve 

 

 

2

 

Scheme

 3 - Solar panel with two storage tanks – main and suplimentary with priority 

 

Sensors   

                              

Schm=3;“dTETa/Tb”

 

 

TS1 – temperature of solar panel 

 

TS2 – temperature of tank  („A”) - main 

 

TS3 – temperature of tank („B”) -suplimentary 

Outputs 

 

R1 – solar pump 

 

R2 – electric heater of tank („A”) 

 

R3 – 3-way valve main/suplimentary tank 

 

Scheme

 3а - Solar panel with one tank with two solar coils and electric heater 

 

Sensors    

                             

Schm=3;“dTETa/Tb”

 

 

TS1 – temperature of solar panel 

 

TS2 – temperature of tank – top („A”) 

 

TS3 – temperature of tank  – bottom („B”) 

Outputs 

 

R1 – solar pump 

 

R2 – electric heater of tank 

 

R3 – 3-way valve top/bottom 

 

Scheme

 4 - Solar panel with one tank with two coils, electric heater and suplimentary heater 

 

Sensors      

                        

Schm=4; “1B+2C+EL”

 

 

TS1 – temperature of solar panel 

 

TS2 – tank temperature 

 

TS3 – suplimentary heating source temperature 

Outputs 

 

R1 – solar pump 

 

R2 – electric heater of tank 

 

R3 – DHW suplimentary heating valve/pump 

 

Scheme

 5 - Solar panel with one tank with two coils, suplimentary heater and heating pump 

 

Sensors    

                           

Schm=5; “SolDhwCh”

 

 

TS1 – temperature of solar panel 

 

TS2 – tank temperature 

 

TS3 – suplimentary heating source temperature 

Outputs 

 

R1 – solar pump 

 

R2 – circulation pump for domestic heating 

 

R3 – DHW suplimentary heating valve/pump  

 

9  

Scheme

 6 – Solar/supplementary heater with two tanks and two pumps, no priority

 

 

Sensors    

         

               Schm=6; “SOL+2P2T”

 

 

TS1 – temperature of heat source 

 

TS2 – temperature of tank – “A” 

 

TS3 – temperature of tank – “B” 

Outputs 

 

R1 – pump for tank “А“ 

 

R2 – electric heater of tank “А”  

 

R3 – pump for tank “B” 

 

10  

Scheme

 7 – Unpreasurized solar panel (open to air system) with el. heater and refill function   

  

 

 

Sensors   

                        

Schm=7; “dT.EL.T1+R”

 

 

TS1 – temperature of solar panel 

 

TS2 – temperature of solar tank 

 

TS3 – not used 

 

Level sensor - Terminals 3 and 4; reads level of liquid

 

Outputs 

 

R1 – solar pump 

 

R2 – electric heater of tank 

 

R3 – refill valve (N.C.) 

Level sensor: C

ontrols electric valve for proper solar panel fill up while monitoring the water level with 

submerged electrode.

 