APPENDIX ONE – Nitrogen Supply Connection
Note 1:
High Pressure Nitrogen Cylinders require caution when handling. Please consult your
supplier for proper handling and connection precautions.
Note 2:
If provided, the High Pressure Regulator cylinder nipple uses an o-ring for hand-tight
sealing. The o-ring must be inspected to assure no cracking or deformation to avoid gas
leaking. Replacement o-rings are # -110 (read: “dash one-ten”) and are available from
automotive, hardware and home-supply stores.
Note 3:
If provided, the High Pressure Regulator is intended only for CGA-580 cylinder valve
connections. This configuration is for use with
Inert Gasses
and may be used with
Nitrogen, Argon or Nitrogen/CO2 gas blends (beer gas) for preservation and dispensing
functions in n2Vin.
Note 4:
If provided, the Regulator Set is pre-fitted with a barb fitting onto which the ¼” plastic
nitrogen supply line will slip. Before fitting the Tube onto the Barb, look at your setup and
be sure it is as you want it.
Though it might require drilling a 3/8” hole in the counter, you can place the nitrogen
Cylinder in a cabinet beneath the system. The cylinder can stand vertically or lie on its
side.