background image

n

2

Vin

Setup and Operations Manual © 2008

16

In customer self-select environments, typically the VIP, Frequent Diner, or other CRM

utilities are used in conjunction with in-house or third party administered Customer Loyalty

card programs.

n2-Infinity-3 allows operators a complete range from simple 3-glass service to creating

individually tailored customer kiosk wine sampling stations fully integrated with the

restaurant’s existing POS. (Example shown below used Future POS)

Summary of Contents for n2Vin

Page 1: ...Wine Service Equipment Operations Guide Rev 2 March 20 2010 ProWine Products 2010 ProWine Products 4269 Lincoln Rd Suite 100 Holland MI 49423 616 494 0100 www n2Vin com...

Page 2: ...without an electrical connection to provide non refrigerated wine preservation and dispensing service at room temperature In this instance the glass door must be removed and stored safely to avoid mo...

Page 3: ...you have done very little that is different from the professional handling of some of the world s most precious vintages some of which you may in fact own Because of their natural cork closures many...

Page 4: ...rgon cylinders as it does to Nitrogen so you can experiment with gas options Sparging is a term used in the wine industry to connote flushing air out of a vat to halt maturation and or prevent oxygen...

Page 5: ...lass gone there s now twice as much air space in the bottle You vacuum You now have x 2 x X number of O2 molecules remaining in the headspace In other words after vacuuming from the second pour you ha...

Page 6: ...Bottle Heads Each has a valve on it UP is ON DOWN is OFF When not connected to a bottle these valves must be in the OFF DOWN position or you will loose gas When connected the valves should be left in...

Page 7: ...E The Cover Plate hangs from the light box at the top of the refrigerated cabinet behind the glass door As shipped you ll need to pry up the two hanger tabs on the back of the panel They should be lif...

Page 8: ...he surface on which you place the system is flat fairly level and near an electrical outlet This is a liquid dispenser placement is best on impermeable surfaces Finished wood furniture should be prote...

Page 9: ...or your wallpaper Setting REGULATOR PRESSURE With the Red Low Pressure Regulator turned to OFF fully Counterclockwise open by turning Clockwise 3 full turns This will be approximately 3 psig pounds o...

Page 10: ...plied regulators set to 3 4psig Tilt a wine glass toward the Trip Lever on the Tap and fully depress the glass against the Lever Pull the glass back when it is at a desirable level If the flow was too...

Page 11: ...to avoid compressor operation and the heat output from it while still providing power for the internal lighting Contact ProWine or your dealer for special conditions such as this as there are several...

Page 12: ...to the right will be a few degrees cooler Wines placed in front and to the left of the midpoint will be a few degrees warmer Active Bottles those in service should be placed across the middle of the B...

Page 13: ...kwise direction When the bottle is properly connected you should just be able to lift it by the bottle head without loosening or pulling it out Turn the Bottle Head gas valve on by moving it UP When t...

Page 14: ...l to make certain you do not leave cotton fibers at the Tap orifice With towel or paper towel twist wrap a small tight corner that will fit into the Tap barrel moisten it with hot tap water and insert...

Page 15: ...h wine are debited from pre paid user cards n2 I 3 is a sophisticated system that requires calibration and initial setup to be performed by experienced personnel The system does not require a full tim...

Page 16: ...are used in conjunction with in house or third party administered Customer Loyalty card programs n2 Infinity 3 allows operators a complete range from simple 3 glass service to creating individually t...

Page 17: ...rdware and home supply stores Note 3 If provided the High Pressure Regulator is intended only for CGA 580 cylinder valve connections This configuration is for use with Inert Gasses and may be used wit...

Page 18: ...Leland Disposable Nitrogen Cylinders remove the two top back screws and install the J Cylinder Cradle Leland Disposables require a specialized non adjustable 5PSIG regulator APPENDIX TWO Gas Suppliers...

Page 19: ...Gas Valve is ON and your gas supply is active Connect the bottle normally to a Bottle Head tighten the seal turn the Bottle Gas Valve ON and dispense about one ounce into a glass or cup Turn the Bott...

Page 20: ...go di Caldaro young Spanish and Portuguese reds vin de pays etc 50 F 10 C California and Australian Chardonnay Sauternes top white C te d Or Burgundy sweet German Wines Rhine and Mosel Kabinett and Sp...

Page 21: ...ost affected by the relative difference between the desired temperature setting in the cabinet and the ambient temperature of the room in which n2Vin is being used If the n2Vin temperature is low and...

Page 22: ...pour modifier et sauvegarder la valeur nouvellement affich e Appuyez sur pour sortir de l ajustement et afficher la temp rature interne actuelle Si aucun nouveau bouton n est appuy dessus apr s 10 se...

Page 23: ...t de temp rature chelle 0 C 1 F 0 D4 Retardement du d clenchage du compresseur 0 10 min 2 min C2 Alarme de haute temp 50 C 122 F 40 C 104 F E5 Compensation de la temp ambiante 10 10 C 18 18 F 0 C3 Ala...

Page 24: ...ture ambiante atteint la temp rature r gl e 4 La fonction de l alarme Quand la temp rature ambiante est plus haute que C2 ou plus basse que C3 l alarme est initi e et sonnera apr s un temps de C4 Le s...

Page 25: ...ately 3OZ 85 grams of refrigerant APPENDIX SEVEN Decommissioning If the n2Vin is to be stored or be otherwise inactive and without being connected to wine bottles it is essential that the system be th...

Page 26: ...of such service Certain exceptions apply to this warranty Owners and or their operators must follow the guidelines set forth in this Manual Damage resulting from transportation accident misuse and ab...

Page 27: ...mmag e remplacez la en premier 110 3 8 X 9 16 X 3 32 mur Installez le r servoir d azote l o il ne tombera pas verticalement ou horizontalement Fermez le vis rouge sur le r gulateur puis r ouvrez le 3...

Page 28: ...rogen cylinder somewhere it won t fall on your foot standing or horizontal Close RED regulator knob then reopen 3 1 8 full turns That will be 4psi Turn Master Gas Valve lower left of dispensing panel...