3
1-2 Default settings for each barcode
Table 1-3. Default settings
Code type
Read
enable
Check digit
verification
Check digit
transmission
Min. code
length
Proprietary
code ID
AIM
code ID
UPC-A
√
√
√
(12)
2
A
]Em
UPC-E
√
√
√
(8)
2
D
]Em
EAN-13
√
√
√
(13)
2
A
]Em
EAN-8
√
√
√
(8)
2
C
]Em
ISBN/ISSN
1
√
√
√
(13)
2
A
]Em
Code 39
√
- - 1 M
]Am
Interleaved 2 of 5
√
- - 6 I
]Im
Industrial 2 of 5
-
-
-
4
H
]Im
Matrix 2 of 5
√
- - 6 X
]Im
Codabar
√
- - 4 N
]Fm
Code 128
√
√
- 1
K
]Cm
Code 93
√
√
- 1
L
]Gm
Code 11
-
√
- 4
V
-
MSI/Plessey - - - 4 O
]Mm
UK/Plessey
√
√
- 1
U
]Mm
UCC/EAN 128
√
√
- 1
K
]Cm
China Post
√
- - (11)
2
T ]Im
GS1 DataBar
√
- - (16)
2
R ]em
GS1 DataBar Truncated
3
√
- - (16)
2
R ]em
GS1 DataBar Limited
√
- - (16)
2
R ]em
GS1 DataBar Expanded
√
- - 1 R
]em
Note:
1
The settings for ISBN/ISSN and EAN-13 must be the same.
2
Fixed-length barcodes.
3