ProVisual PTZ-501C User Manual Download Page 4

ProVisual PTZ-501C – PTZ Keyboard Controller Manual 

                   

www.provisualusa.com 

4 | 

P a g e

 

 

 

With  VGA  input,  the  keyboard  can  working  with  a  display;  can  connect  with  DVR,  PC  ECT.  The  max  input  resolutions  1280X720, 

1024X768, 800X600, 

 

USB Interface, use to connect with the PC. By this connect way, the keyboard can working as an aim object. 

Video interface used for camera 

           

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2. 2 - Connect Matrix 

Can  control  the  PELCO  CM6700,  CM6800  matrix.  Follow  are  the  connection  way  of  matrix  PELCO  CM6700,  to  show  the  steps  of 

connection.  Cover  board  of  CM6700  matrix  has  the  interface  of  RS422  (REMOTE  KEYBOARD(s)),  connect  it  to  the  RS422  on  the 

keyboard, longest distance is 1200m 

 

2. 3 - Direct Connect With Dome 

Keyboard connects the Dome with RS485.The RS485 interface of the Dome is on the commutator of the Dome. Press the metal button in 

the  hanging  frame,  open  the  commutator,  will  find  a  4bit  power  jack,  follow  the  surface  instruction  to  find  RS485  (A+,  B-)  follow  the 

instruction. Maybe a different connects way when come from different manufacturer.       

485 Match ON/OFF 

Figure 2-1.1   

 

Video Input 

RS485 

Power Input 

Display Screen 

LOCK 

VGA Input 

USB 

ON/OFF 

Summary of Contents for PTZ-501C

Page 1: ...PTZ 501C ProVisual PTZ Keyboard Controller User Manual www provisualusa com...

Page 2: ...7 3 6 Set Dome Function 8 3 6 1 Pre set 8 3 6 2 Pattern 8 3 6 3 Cruise 8 3 7 Call Dome Main Menu 8 3 8 Matrix Control 8 3 8 1 Call Matrix Main Menu 8 3 8 2 Confirm After Program 8 3 8 3 Change Object...

Page 3: ...kinds of protocols Can control the Iris Focus and Zoom Can set and call the preset run the scanning the pattern and the tour Can control the matrix and through which can control the dome indirectly E...

Page 4: ...PELCO CM6700 to show the steps of connection Cover board of CM6700 matrix has the interface of RS422 REMOTE KEYBOARD s connect it to the RS422 on the keyboard longest distance is 1200m 2 3 Direct Con...

Page 5: ...bus of RS 485 all the keyboard can control any dome among them under this way the add of the main keyboard should be 1 and baud rate should be 9600bps as figure 2 4 2 Keyboard Caution 1 The max quanti...

Page 6: ...ease because different system have some different special operation ways so should consider the actual requirement when operation in some special systems TFT display screen Keys Zone Joystick Figure 2...

Page 7: ...menu DOWN for the next menu RIGHT for the sub menu or save the setup RIGHT for exit Direct proportion between the speed of the Dome and the lean angle of the navigation keys large lean angle faster ro...

Page 8: ...monitor 3 8 Matrix Control 3 8 1 Call Matrix Main Menu SHIFT SET Call the main menu the menu will display on the object monitor How to use the keyboard Setting the matrix Please refers the matrix oper...

Page 9: ...s TFT Picture4 1 1 2 Figure 4 1 1 2 3 Press 1 again will show the picture Picture4 1 1 3 Figure 4 1 1 3 4 Press 1 to select the ID Setting Picture4 1 1 4 Figure 4 1 1 4 Use the Number Keys on the keyb...

Page 10: ...ll display as figure 4 1 4 1 Figure 4 1 4 1 Press PREV or use the joystick turn LEFT back to previous menu The keyboard menu will display all the keyboard setting information include the keyboard mode...

Page 11: ...previous menu Press 3 enter the clear the Preset to clear preset information as picture 4 2 1 6 show Figure 4 2 1 6 Input the PRESET NO which you want to clear and press the Enter to clear it and it...

Page 12: ...the pattern directly Pattern setting After enter the pattern setting menu move the dome do the suitable position and press the 1 to start record the scan track The screen will display Start like the...

Page 13: ...ER and will display Success and back to previous menu Figure 4 2 4 2 Press 3 Run the TOUR Warning 4 3 Protocol Setup Enter the menu as picture 4 1 1 1 Press 3 enter the Protocol setting as picture 4 3...

Page 14: ...save 4 Back light adjust 5 USB model mode 6 Picture brightness adjust 7 Picture contrast 8 Picture color 9 Language 10 System initialization 4 5 Exit The Keyboard Menu Enter the menu as picture 4 2 1...

Page 15: ...nnects lots of equipment to the RS485 Bus the maximum transmitting distance will be decreased To increase the maximum transmitting distance do the contrary Connection and Terminal Resistance The RS485...

Page 16: ...onds at intervals to the controller or dose continuous operation without stop In such circumstances the factory will recommends the usage of Rs485 distributor The distributor can change the star confi...

Page 17: ...AN High speed dome Adjust the image to object position press Set to input 2 then press Scan to set scan right limit 1 SCAN High speed dome Input 1 press Scan to run scan SET N PATTERN High speed dome...

Page 18: ...PREV to back PAL NTSC ON OFF 000 255 000 100 Mouse Pckey none 000 255 000 255 000 255 CHN ENG ON OFF 1 Set left limit 2 Set right limit 3 Run scan 1 Save preset 2 Show preset 3 Clear preset 1 Pattern...

Reviews: