background image

6

7

No fl ame - F1

Boiler is switched off, for 
example by reason of 
gas supply failure. LED 4 
under symbol    fl ash. 
Boiler can be restarted by 

switching off and on (from position „

I

” to 

position „

0

“ and again to position „

I

“ by 

mains on/off switch). If  fault is frequent, 
call service centre.

Loss of circuit heating water - F0

Pressure is under 0,7 
Bar. Boiler is switched off, 
LED 1 and LED 4 under 
symbols      and     fl ashes. 
After fi lling system up to 

1- 2 Bar the boiler automatically starts. 
For fi lling can be used refi lling valve at 
the bottom of boiler (see fi g. 4). If fault is 
frequent, call service centre.

Other boiler faults (from F2 to F8)

Boiler switched off itself. 
LED 4 under symbol 
fl ash.   It is necessary to 
call service centre. 

Fault messages

fi g. 3

Operation diagram

Boiler memory fault - F9

Boiler works, but possi-
bility changes in setting 
exists. LED 3 under sym-
bol        lights continuously. 
Switch the boiler off and 

on (from position „

I

” to position „

0

“ and 

again to position „

I

“ by mains on/off 

switch). Then check boiler parameters 
(see Water temperature setting). Let 
check the boiler setting by service centre 
occasionally.

Factory setting:
- DHW temperature 60°C
- CH temperature    50°C
- max. heating power 15 kW

Note: 

The preparation for and commencing 

of the boiler operation may only be carried 
out by a specialised service centre!

Before starting the boiler when it 
has been put into operation, check 
the following facts:

•  The power cord must be plugged into the 

socket.

• The gas valve that feeds the boiler must 

be open.

•  The water pressure in the heating system 

should be between 1 and 2 bar
Now the boiler is ready to be started.

Boiler start

Set the mains on/off switch to the “on” 
position (“I”). Display light up.

Note: 

In case of safety switch-off due to 

extinction of fl ame or the fl ue thermostat 
reaction (version 24 BOV) LED 4  under 
symbol      starts fl ash. Boiler can be un-
blocking by switching the boiler off and on 
(from position „

I

” to position „

0

“ and again 

to position „

I

“ by mains on/off switch).

In case of safety switch-off due to overheat 
thermostat  Led 4 under symbol       fl ash 
too, but boiler can be unblocking only by 
service centre and this act is not guarantee 
repair. 

Warning: 

The boiler must not be operated 

if the safety elements (e.g. overheat 
thermostat, fl ue termostat)  are dis abled 
or re placed with elements different from 
those specifi ed by the manufacturer.

Boiler switch-off

 

Set the mains on/off switch to the “off” 
position (“0”).

If the boiler is going to be switched off 
for a longer time, it is recommended to 
disconnect boiler from the electricity source 
and close gas valve. This must be done 
with reference to ambient temperature, 
because there is the risk of freezing boiler 
and system in frost weather.

Setting SUMMER mode (only DHW)

•  Start the boiler;
• Select  “

– –

” for CH temperature as 

described under Control and Signalling  
(CH temperature setting);

•  Activate the basic state  by MODE button.

Setting WINTER mode (CH + DHW)

•  Start the boiler;
•  Select the CH temperature instead of “

– –

” 

as described under Control and Signalling 
(CH temperature setting);

•  Activate the basic state  by MODE button

Boiler Start and Switch-Off

Operation without a room 
thermostat 

Boiler keeps CH temperature on 
setting value. The room thermostat is 
not connected; its contacts must be 
interconnected (by utilizing a jumper).

• Set the desired temperature value as 

described under Control and Signalling 
(CH temperature setting);

Operation with a room thermostat

Boiler keeps CH temperature on setting 
value, with breaks in operation dependent 
upon the temperature in the room in which 
the thermostat is installed. The radiator in 
that room must not be equipped with a 
thermostatic valve head. The settings are 
the same as the operation without the room 
thermostat, but the jumper is removed and 
the room thermostat is connected to the 
contacts.

Boiler Regulation

Pressure in system

DHW temperature

CH temperature

Pressing MODE button

Keep the pressure CH 

on 1 - 2 Bar by fi lling 

or draining system

Confi rm by MODE

Confi rm by MODE

Summary of Contents for Leopard 24 BOV

Page 1: ...b c Leopard User and Installation Instructions 24 BTV v 17 24 BOV v 17 XXXX Wallhung gas boiler DHW preparation Power 9 24kW ...

Page 2: ...the harmonization of the Laws of the Member States relating to the electrical equipment designed for use within certain voltage limits 3 Directive 89 336 EEC on the approximation of the Laws of the Member States relating to electromagnetic compatibility 24 BTV BOV Table of contents Introduction 2 Important notes 2 Safety of life and property 3 User instruction Control and signaling 4 Boiler indica...

Page 3: ...eeze protection is inactivated then When the life cycle of the boiler or its parts has expired they should be disposed of in an environmentally friendly manner Producer do not provide warranty and do not answer for damage due to infringement of conditions mentioned in these Instructions valid Regulations and Standards correct installation and use conditions mentioned in Guarantee Certificate and S...

Page 4: ...cation in C required value Domestic hot water tap is open LED 2 under symbol lights continu ously DHW temperature corresponds with requi red value in certain DHW flow range Water pressure in central heating system in Bar LED 1 under symbol lights continuously Re commended range is 1 2 Bar Pressure is displayed for 30 sec after one pressing button Domestic hot water temperature setting in C Tempera...

Page 5: ...f and on from position I to position 0 and again to position I by mains on off switch In case of safety switch off due to overheat thermostat Led 4 under symbol flash too but boiler can be unblocking only by service centre and this act is not guarantee repair Warning The boiler must not be operated if the safety elements e g overheat thermostat flue termostat are disabled or replaced with elements...

Page 6: ...ystem The maximal power 23 kW is always available for preparing DHW Only service centre authorized by manufacturer can change heating power in accordance with requirement of heating system Servicing and maintenance Refilling water to heating system Caution The boiler is installed as part of a sealed system which must only be drained and filled by a competent person Common user can fill and drain b...

Page 7: ...n the refilling valve and simultaneouslywatchthepressureincrease on the display Pressure is displayed only 30 second after pressing MODE button The valve is opened counter clockwise closed clockwise Fill the system to pressure 1 2 bar When the desired pressure is achieved shut the valve without applying excessive force and check that the water pressure is not growing which would occur if the valve...

Page 8: ...7 Adjustable temperature range C 35 60 Flowrate at 25 C temperature increase litre per min 12 5 30 C temperature increase litre per min 10 8 35 C temperature increase litre per min 8 8 Electrical data El voltage frequency V Hz 230 50 El power input W 135 El protection class IP 45 El current A 0 6 Connections Heating water in out G 3 4 DHW in out G 1 2 Gas G 1 2 Flue gas and air ducts Flue duct air...

Page 9: ...onal parameters and or defects caused by the use of the anti freeze mix tures will not be covered by the warranty Prior to the final assembly the heating cir cuit pipes should be flushed by pressure water several times For older circuits that have already been in use the flushing stream direction must be opposite to that of the heating water Installation of a sludge separator is recom mended in th...

Page 10: ... are prohibited from being inserted in the connecting flue pipe The 24 BOV takes combustion air from the space around it There must be possibility of direct space ventilation and sufficient combustion air supplies comply with valid standards Delivery completeness BTV BOV boiler is delivered in assembled state and functionally tested Delivery contains see fig 9 1 Boiler 2 User and installation inst...

Page 11: ...ad and chemical agents and replacement must always be arranged prior to the end of the life cycle and or deterioration of their parameters according to their manufacturer s instructions Note after connecting of boiler to heating system remove plastic stoppers which are placed in boiler outlets DHW system The DHW pressure should be between 1 an 6 bars if it is higher a reduction valve must be insta...

Page 12: ...24 BTV BOV G20 model is designed for natural gas with 2 0 kPa rated pressure in the network and the calorific value of 9 to 10 kWh m3 The internal gas piping and the gas meter must be dimensioned for all gas appliances of the respective user The boiler s connection branch s rated inner diameter should be at least DN 1 2 but one degree higher DN 3 4 is recommended The 24 BTV BOV G30 model is design...

Page 13: ...ents 1 m horizontal 2 m vertical The external vent should always be oriented to the open space not to doors windows or grilles If this requirement cannot be met the minimum distances must be preserved as follows a opposite between the façade with the external vent and a façade parallel to it 2 m if the opposite façade has no windows or grilles 1 m if neither façade has any windows or grilles in it...

Page 14: ... sealing ring G on the air duct A Push the completed duct section through the wall opening so that the G ring is aligned with the outside surface of the wall Place the collar and clip onto the duct and elbow check proper sealing of both inside and outside sections of the duct Note The maximum horizontal length is 1 elbow plus 3 m 4 equivalent metres if the horizontal route s equivalent length is m...

Page 15: ...protective grounding wire the electrical plug in the socket must always be accessible without obstacles Use of adaptor plugs extension cords etc is prohibited The boiler is protected by tube fuse 125 mA 250V placed on PCB Only a person with adequate electrical engineering qualifications can be allowed to install the socket and the thermostat thermostat installation requires utilization of the boil...

Page 16: ...28 29 24 BTV Electrical diagram fi g 23 24 BOV Electrical diagram fi g 24 ...

Page 17: ...PG is required it is necessary replace gas valve and burner platform and then set the boiler to specified parameters Conversion must only be car ried out by a competent person authorised by the manufacturer Gas valve and burner platform are part of Conversion set This set contains all needful parts and Instructions for conversion ...

Page 18: ...Leopard User and Installation Instructions 24 BTV v 17 24 BOV v 17 XXXX Wallhung gas boiler DHW preparation Power 9 24kW ...

Page 19: ...XXXX Wallhung gas boiler User and Installation Instructions ...

Reviews: