Main Tripod lateral
attachment point
Rope Pulley #1
Rope Pulley #2
Trolley "A"
T-lock
Rope
RUP 502-A
or
RUP 503
Trolley "A"
locking holes
SDW energy absorber
ALWAYS USE Trolley "A" detent pin
for lock Trolley "A" position during lifting loads.
Trolley "A"
detent pin
Trolley "A"
locked in one of available
working positions.
T-lock for
Trolley "A"
support
INSTALLING RUP 502-A / RUP 503 RESCUE LIFTING DEVICE TO THE TM 12-2 HEXAPOD FULL SET
The TM 12-2 hexapod full set can be used with RUP 502-A / RUP 503 rescue lifting devices. RUP 502-A / RUP 503 should be installed on the main tripod reinforced leg. The grip of the
rescue lifting devices should be fastened on the locking hole situated on the internal wall of the reinforced leg. Rope pulley #1 should be attached to the Main Tripod Lateral Attachment
Point using connector. Rope pulley #2 should be attached to the Trolley "A" with connector. Working rope should pass through the pulleys #1 and #2 wheels. Position of the Trolley "A"
should be secured with Trolley "A" detent pin installed in one of Trolley "A" locking holes and back of the Trolley "A" should be support by T-lock. For proper and safe installation and use of
the RUP 502-A / RUP 503 please refer their instruction manuals.
Energy absorber SDW MUST BE ALWAYS USED
in conjuction with RUP series rescue lifting devices.