INSTALLING THE ROPE GRAB ON THE WORKING ROPE
CONNECTING THE WORKING ROPE TO THE STRUCTURAL ANCHOR POINT
Attention!
Structural anchor point
should has static
resistance min.12 kN.
The shape of the structural
anchor point should not
let self-acting
disconnection of the rope
It is recommended to use
certified and marked
structural anchor point
complied with EN 795.
Structural
anchor point
min. 12 kN
Structural
anchor point
min. 12 kN
Structural
anchor point
min. 12 kN
Structural
anchor point
min. 12 kN
FORBIDDEN !
FORBIDDEN !
1
3
2
4
1. Rotate the safety catch and raise rope grab locking
lever.
2. Position rope grab on the working rope.
The arrow
placed on the rope grab must be directed to the top
ending of the rope.
3.
Release safety catch and the lever. Then the rope is
prevented from slipping out.
4. Attach oval type snap hook to the rope grab locking
lever and then attach the snap hook to the front
attaching point of safety harness. Make sure that the
snap hook gate is closed and locked.
Attention:
The snap hook inserted into the locking lever hole is
additional protection against accidental disconnection of the
rope grab. It is impossible to take off the rope grab from the
working rope without removing the snap hook from the
locking lever.
The rope grab must be attached to the safety harness only
with a single oval type snap hook, without any additional
elements.
CONNECTING THE ROPE GRAB TO THE SAFETY HARNESS
!
the rope grab must be connected only with a single oval type snap hook which complies with EN 362 to front
attaching point of full body harness. The full body harness must comply with EN361
!
it is strictly forbidden to connect the rope grab to the work positioning belt
!
it is strictly forbidden to add any additional element between the snap hook and attaching point of harness
o
max. 45
A
X
B
stosować wyłącznie z liną 12 mm
Rok produkcji: 2000
MECHANIZM
ZACISKOWO-PRZESUWNY
NR SERII
PROTEKT
Łódź ul. Starorudzka 9
GÓRA
L
stosować wyłącznie z liną 12 mm
Rok produkcji: 2000
MECHANIZM
ZACISKOWO-PRZESUWNY
NR SERII
PROTEKT
Łódź ul. Starorudzka 9
GÓRA
Structural
anchor point
min. 12 kN
Structural
anchor point
min. 12 kN
REQUIRED FREE DISTANCE BELOW WORKING LEVEL
!
structural anchor point to which will be connected working rope should be situated above working position and should has static resistance min. 15kN.
Free distance below the working surface depends on the length of the working rope under the worker - see the table and drawing A:
o
!
during horizontal moving of the worker, the working rope deflection from the vertical line up to 45 is allowed - see the drawing B.
Length of the rope over the worker [m] - L
Free distance below the working surface [m] - X
10 20 30 40 50
3,2 4,60 6,00 7,40 8,80
Using the AC 040 fall arrester in connection with fall arrest system must be compatible with use instructions of the fall arrest systems and obligatory
standards:
- EN361 - for the safety harness;
- EN353-2, EN354, EN362 - for the fall arrest systems;
- EN 795 - for anchorages
- EN358 - for the work positioning systems.
!
personal protective equipment shall only be used by a person trained and competent in its safe use.
!
personal protective equipment must not be used by a person with medical condition that could affect the safety of the equipment user in normal and
emergency use.
!
a rescue plan shall be in place to deal with any emergencies that could arise during the work.
!
it is forbidden to make any alterations or additions to the equipment without the manufacturer's prior written consent.
!
any repair shall only be carried out by equipment manufacturer or his certified representative.
!
personal protective equipment shall not be used outside its limitations, or for any purpose other than that for which it is intended.
!
personal protective equipment should be a personal issue item.
!
before use ensure about the compatibility of items of equipment assembled into a fall arrest system. Periodically check connecting and adjusting of the
equipment components to avoid accidental loosening or disconnecting of the components.
!
it is forbidden to use combinations of items of equipment in which the safe function of any one item is affected by or interferes with the safe function of another.
!
before each use of personal protective equipment it is obligatory to carry out a pre-use check of the equipment, to ensure that it is in a serviceable condition
and operates correctly before it is used.
!
during pre-use check it is necessary to inspect all elements of the equipment in respect of any damages, excessive wear, corrosion, abrasion, cutting or
incorrect acting, especially take into consideration:
- in full body harnesses and belts - buckles, adjusting elements, attaching points, webbings, seams, loops;
- in energy absorbers - attaching loops, webbing, seams, casing, connectors;
- in textile lanyards or lifelines or guidelines - rope, loops, thimbles, connectors, adjusting element, splices;
- in steel lanyards or lifelines or guidelines - cable, wires, clips, ferrules, loops, thimbles, connectors, adjusting elements;
- in retractable fall arresters - cable or webbing, retractor and brake proper acting, casing, energy absorber, connector;
- in guided type fall arresters - body of the fall arrester, sliding function, locking gear acting, rivets and screws, connector, energy absorber;
- in connectors - main body, rivets, gate, locking gear acting.
THE ESSENTIAL PRINCIPLES FOR USERS OF PERSONAL PROTECTIVE EQUIPMENT AGAINST FALLS FROM A HEIGHT
!
after every12 months of utilization, personal protective equipment must be withdrawn from use to carry out periodical detailed inspection. The periodic
inspection must be carried out by a competent person for periodic inspection. The periodic inspection can be carried out also by the manufacturer or his
authorized representative.
In case of some types of the complex equipment e.g. some types of retractable fall arresters the annual inspection can be carried out only by the manufacturer
or his authorized representative.
!
regular periodic inspections are the essential for equipment maintenance and the safety of the users which depends upon the continued efficiency and
durability of the equipment.
!
during periodic inspection it is necessary to check the legibility of the equipment marking.
!
it is essential for the safety of the user that if the product is re-sold outside the original country of destination the reseller shall provide instructions for use, for
maintenance, for periodic examination and for repair in language of the country in which the product is to be used.
top ending