NOTE
Please ensure that you lay the battery in the
window transmitter on top of the metal tab and
not below it.
3. Press the upper casing section onto the lower
casing section.
Attaching the magnet
Fix the magnet in place in accordance with
figure 4.
Open and close the roller shutter once after attachment.
The transmitter should flash at least once for each
activation. Proceed as follows to attach the magnet:
4. Attach the lower magnet casing section and the lower
sensor casing section in the correct position using the
included double-sided sticky pad.
Alternatively there is a prepared hole in the lower casing
sections through which the magnet and the sensor can
be screwed to the window frame.
5. Drill a 5 mm hole through the window frame and feed
the sensor cable to the outside into the lower casing
section at the correct point.
6. Insert the magnet and the sensor and check the
functioning of the roller shutter sensor.
CAUTION!
The distance between the roller shutter sensor and
the magnet may not exceed 6 mm!
7. Open the roller shutter again. The green LED (OPEN)should
flash briefly if the sensor has been installed correctly.
8. Now close the roller shutter. The red LED (CLOSED) will
flash briefly.
9. After all functions have been successfully tested the
transmitter, sensor and magnet must be screwed to the
window/window frame. There is a prepared hole in the
lower casing section of the roller shutter transmitter and
in the lower casing of the magnet and sensor. This
allows you to screw the roller shutter transmitter,
magnet and sensor to the window/window frame.
This prevents them from falling down unintentionally
during operation.
10. Close the casing on the transmitter, the magnet and the
sensor with the correct cover.
Attachment points:
• It must be ensured that the gap between the magnet
and the sensor is less than 6 mm when the roller
shutter is open.
• The contact must be attached to the top or side window
frame and casement in such a way that the distance
between the two casing sections is less than 6 mm
when the window is closed! Use the included packing
(U)
to make these adjustments.
• We recommend attaching the contact and the magnet
with the double-sided sticky tape before the final
attachment and only to screw them in place at the end.