CRW 200 Service Manual
6/13
4.2. The retracting spring set maintenance and inspection
4.2.1
•
Clean and inspect the
constituent parts. Pay
special attention on the
retracting spring internal
ending (1) shape.
•
Lubricate the retracting
spring, using openings
(1)
and
(2)
from cable
drum side.
4.3. The drum set maintenance and inspection
4.3.1
•
Prepare the Rotating Jig. Seat the
CRS
04-04 Extension Kit
(1)
in the CRS 04
base
(2)
.
4.3.2
•
Install the cable drum set on the
rotating jig.
•
Test the connector for correct
operation. If the connector is equipped
with fall indicator, check if it is not
deformed.
•
Unwinding the cable from the drum,
inspect it against: broken wires,
unbraided strands, permanent
deformations, excessive corrosion.
•
Check the rope ferrules
(3)
against
cracks or deformation.
•
Check if the rope's end
(4)
project
outside the ferrule.
•
Replace the entire cable set in case of
any damages or abnormality.
4.3.3
•
Take off the cable drum from the
Rotating Jig.
•
Unscrew the screwing connection
(5)
,
(6)
,
(7)
and dismantle all
parts of the set.
•
Check all the parts against:
cracks, deformation and
corrosion. Replace wrong parts if
necessary.
2
1
3
4
5
6
7
2
1
lubricate