3
Q80S_2014
24V
ac
230V
ac
F2
J5
J1
JP4
JP5
JP6
JP8
JP7
1 2 3 4 5 6 7 8 9 10 11
15 16 17
18 19 20
JP1
JP2
JP3
K3
K1
K4
22
21
T2
U1
TR2
C8
C21
C24
ALIM.
230Vac
5A
230Vac
JP9
12 13 14
FR1
V1
FR2
PROTECO S.r.l.
Via Neive, 77 - 12050 Castagnito (CN) ITALY Tel. +39 0173 210111 - Fax +39 0173 210199 [email protected] - www.proteco.net
2. WIRING DIAGRAM and COMPONENTS
Display BUTTONS Legend
ENTER
EXIT
INCREASE
or
START
command (when not programming)
DECREASE
or
PEDESTRIAN START
command (when not programming)
DISPLAY
= segments display
J1
= radio module
J5
= plug for optional modules
F2
= 230V fuse 5A
FR1
= 24V fuse 1.6A (self-restorable)
FR2
= 24V fuse 0.6A (self-restorable)
V1
= secondary varistor
K1/K3
= motor relay
K4
= blinker relay
TR2
= filter
JP1
= AERIAL terminal block
JP2
=
secondary transformer plug 24Vac
JP3
=
main transformer plug 230Vac
JP4
= CONTROLS terminal block
JP5
= PHOTOCELLS terminal block
JP6
= BLINKER terminal block
JP7
=
input
Motor
JP8
=
input LIMIT-SWITCH
JP9
= 230V MAIN power/earth terminal block