background image

MODELS COVERED

INTEGRA  III  SYSTEM

The  overall  attenuation  range  of  the  VCA  cards  may  be
modified in the field, by using a series resistor and changing the
value of the remote potentiometer.
The input sections are followed by a summing amplifier, on
mixing units, and then by a line amplifier circuit (on all models)
depending  on  the  model  selected.    The  output  section  is
transformer  isolated  with  a  high  quality,  600  ohm  line
transformer.
All  units  may  be  linked  together  to  create  larger  mixing
networks.  Both  the audio output, and the link output may be
strapped for PRE or POST  VCA. This feature allows the audio
output level to be remotely controlled, while the link output is
fed to other units at full volume, or the link output level may be
post VCA while the main output remains at full volume. This
PRE/POST VCA feature is particularly useful when logging
recorders are used.
Both models are designed to mount in the Models  857B or the
858B Card Frame Packages. The all VCA units  may be mixed
or matched with other INTEGRA III SYSTEM cards to create
a complete audio system.  The Model 858B will allow mount-
ing of 9 cards and an internal power supply.  The Model 857B
will allow mounting of up to 10 cards with an external power
supply.

The Models  891 to  898 Remote Controlled Audio Cards are
designed  to  operate with either microphone or line level
input signals,  with remote volume control, and are intended
for use in professional audio systems.
Typical    applications    are  public  address  systems,  court-
rooms,  sales  presentation  rooms,  headphone  listening
systems, and recording systems. The actual application of the
amplifiers  is  found  in  buildings  such  as  airports, factories,
courthouses,  casinos,  convention  centers, libraries,  hotels,
racetracks,  training  systems,  corporate boardrooms, etc.
The  models  891,  892,  893,  and  894  have  line  level  inputs.
The  models  895,  896,  897,  and  898  have   microphone
level inputs.  All  inputs are transformer isolated. The gain of
each input stage is adjustable via a trimpot mounted on the
backplane assembly. The gain adjustment is independent of
the attenuation adjustment.
The attenuation is accomplished using an on-board VCA
(voltage controlled amplifier) circuit in each input section.
The  VCA  is  controlled  via  a  0-5  volt  DC  control  signal,
generated on-board, which is adjusted by a remotely mount-
ed 10K linear potentiometer. The default for the attenuation
is zero volts = zero attenuation. This default prevents loss of
signal if the control wires are accidentally cut.

PROTECH

®

891

892

893

894

INSTALLATION & OPERATION MANUAL

MODEL 891 - 898

REMOTE CONTROLLED AUDIO CARDS

www.

protechaudio

.com

INTEGRA  III  SYSTEM

PROTECH

®

CONNECTOR   &    TRIMPOT    DRAWING

MODELS  892,  893, 894, 896, 897, 898

NOTES:

1
2
3
4
5
6
7
8
9

10
11
12
13
14
15

INPUT  #1  HI

INPUT  #1  LO

SHIELD

H

L

POTS   (2) HI

POT #1 ARM

SHIELD

LINK  OUT

16
17
18
19
20
21
22
23
24
25
26
27
28
29
30

OUTPUT  #1 HI

OUTPUT  #2 HI

OUTPUT  #1 LO

OUTPUT  #2 LO

L

H

POT #2 ARM

POTS (2) LO

TYPICAL OF EACH OUTPUT

INPUT  #2  HI

INPUT  #2  LO

H

L

CH #2
GAIN

CH #1
GAIN

857B  &  858B Backplane Connections

SUMMED OUTPUT
HI
SUMMED OUTPUT
LO

H

L

895*

896*

897*

898*

*Microphone Level Inputs

Model 894A Shown

1/06

Protech  Audio  Corporation,  PO Box 597,  192 Cedar River Road,  Indian Lake,  New York,  12842,  Voice 518-648-6410  Fax 518-648-6395