Auto. mode
You can select “Auto.mode” to do full cycle of recovery, vacuum, oil injection and charge.
In auto. Mode, the machine makes recovery, vacuum, oil injection and refrigerant charge in
sequence automatically, with data preset by users.
Empty used oil vessel before the process.
System setting
Select “system setting” icon and input PW 111111 (left and right arrow to move cursor, up and
down arrow to increase/decrease number) to enter system setting menu. In system setting,
“Language”, “Calibration”, “Database”, “Unit set”, “Empty container weight set” and “Component
test” can be inquired or reconfigured.
Language: Can change operation system language.
Calibration: It is suggested to have only professional technicians to do calibration of load cells. The
load cell calibration is very simple and fast, with just one step, 1kg weight calibration step.
Warning: Misoperation in calibration could bring about serious consequences to equipment or
vehicle A/C system.
Database: Users can access database of refrigerant/oil volume of different car makes and models.
Unit set: To set metric or American imperial unit. The two numbers displayed in the bottom part of
the interface are values of two tank load cells for reference.
Empty container weight set: The total load cell reading equals the sum of empty container weight
and net refrigerantl content value. Thus, increase/decrease empty container weight, can
correspondingly decrease/increase refrigerant value displayed in the main operation interface.
Component test: Users can activate/des-activate different electronic component of the machine.
This is for quick and easy diagnosis for troubleshooting.