![ProTeam GoCartVac Service Manual Download Page 49](http://html1.mh-extra.com/html/proteam/gocartvac/gocartvac_service-manual_1619323049.webp)
Reassemble Switch in Hose Handle
www.pro-team.com 866.888.2168
47
REASSEMBLE SWITCH
Place new switch/BCM in handle.
1.
Place BCM such that wires are closest
to the switch and not against handle
wall.
3.
Ensure stub tube is inserted into angle tube.
Place angled tube into handle.
4.
Confirm copper rings on
angled tube are against the
metal clips on BCM.
5.
Replace handle cover.
6.
Tighten 8 screws holding 2
sides of handle together.
7.
Place switch with the ON position
( I ) facing the stub tube.