3.3
Ethernet Interface
The Ethernet cable should contain an RJ45 connector. It should have a twisted pair cable of
category 5 (CAT5) or higher, which consists of 4 twisted cores and has a maximum
transmission rate of 100 MBit/s (CAT5).
3.3.1 Ethernet Pin Assignment at the RJ45 Socket
Note:
The device supports the
Auto Crossover
function. The RX and TX
can be switched. The following figure shows the RJ45 standard pin
assignment.
Pin
Signal
Description
1
TX+
Transmit Data +
2
TX
–
Transmit Data
–
3
RX+
Receive Data +
4
Term 1
Connected to each other and
terminated to PE through RC circuit*
5
Term 1
6
RX
–
Receive Data
–
7
Term 2
Connected to each other and
terminated to PE through RC circuit*
8
Term 2
*Bob Smith Termination