3.5
Downloading the Sample Program to the Processor
Note: The key switch on the front of the ControlLogix processor must be in the REM or Program position.
1
If you are not already online with the processor, open the
Communications
menu,
and then choose
Download
. You do not have to download through the
processor’s serial port. You may download through any network connection.
2
When communication is established, Studio 5000 (or RSLogix 5000) opens a
configuration dialog box. Click the
Download
button to transfer the sample
program to the processor.
3
Studio 5000 (or RSLogix 5000) compiles the program and transfers it to the
processor. This process may take a few minutes.
4
When the download completes, the configuration program opens another
Confirmation dialog box. If the key switch is in the
REM
position, click
OK
to
switch the processor from
PROGRAM
mode to
RUN
mode.
Note: If you receive an error message during these steps, refer to the Rockwell Automation