MVI69E-MBS ♦ CompactLogix™ Platform
Configuring the Module in RSLogix
Modbus Serial Enhanced Communication Module
User Manual
ProSoft Technology, Inc.
Page 34 of 159
9
This opens the
I
MPORT
C
ONFIGURATION
dialog box. Click
T
AGS
to show the controller
tags in the AOI. You must edit the
F
INAL
N
AME
column of the tags for the second
module to make them unique.
10
Associate the I/O connection variables to the correct module in the corresponding
slot number. The default values are Local:1:I and Local:1:O. You must edit these
values if the card is placed in a slot location other than slot 1 (Local:1:x means the
card is located in slot 1). Since the second card is placed in slot 2, change the
F
INAL
N
AME
to Local:2:I and Local:2:O. Also, you can append a ‘_2’ at the end of the
F
INAL
N
AME
of ‘AOI69_MBS’ and ‘MBS’ arrays as shown below.