9
2.
The fuse holder is located under the AC power receptacle, use the slotted (
–)
screwdriver to loosen the fuse holder.
3.
Replace the fuse with new one.
4.
Put the fuse holder back in place.
VII.
Trouble shooting
Warning:
Before checking the inside of the SS-989 or replacing parts, be sure to
disconnect the power plug. Failure to do so may result in electric shock.
Defect Situation
Possible Problem
Solution
Dead, Doesn’t work
Blown fuse
Change new fuse
SS-989E(110V) 250V 8A
SS-989B(220V) 250V 5A
SS-989E7(127V) 250V 8A
SS-989H(220V) 250V 5A
PCB Board broken
Contact vendor for repair
Soldering Iron does
n’t
heat up
Panel display S-E, plug
didn’t
connect properly
Reconnect the plug of Soldering Iron
Heating Element broken
Replacing heating element
Heat Gun air
Temperature
doesn’t
heat up
Heating Element broken
Replacing heating element
Heat Gun airflow level
abnormal
Internal pipe
obstruction or loosen
caused air leakage
Clearing the internal pipe, reconnect the
pipe tightly.
Pump securing screws
haven’t
loosened
Loosen the pump securing screw which
on the bottom of control station.
Display shows
abnormal
Transportation caused inside PCB
board didn’t connect properly
Open the case, reconnect the PCB
board
Input voltage lower than standard
request
Check with local power service provider
Temperature unit
display abnormal
IC broken
Contact vendor for repair
Summary of Contents for SS-989
Page 11: ...10 SS 989 2 1 SMD _ 480 C 896 F _ _ _ _ SS 989 _ _ _ _ _...
Page 12: ...11 _ _ _ _ SS 989 _ 1 SMD CPU 200 3 1...
Page 14: ...13 B 2 3 3 SMD QFP 1 2 4 2 4...
Page 15: ...14 PLCC 3 4 5 5 QFP 1 2 6 3 7 4 5 6 7...
Page 16: ...15 1 2 3 CAL 1 8 8 2 3 9 4 9 5 9...
Page 17: ...16 6 7 250 482...
Page 19: ...18 2015 Prokit s Industries Co LTD All rights reserved 2015001 C...