REPLACEMENT
FILTER
INSTRUCTIONS
1. Place towel under the
fi
lter system to collect any residual water during
fi
lter
change.
2. Twist the
fi
lter housing counter
‐
clockwise 90 degrees/a quarter turn to the right
and separate the housing from the head. The head has an internal shut
‐
o
ff
built
in but there will be a momentary water spillage from the depressurizing of the
valve. This is normal.
3. Remove the cap from the housing/sump by unscrewing it. Separate the internal
fi
lter from the
fi
lter mount and discard. Replace with new
fi
lter cartridge;
rea aching the
fi
lter mount to the
fi
lter cartridge, placing into the housing/sump
and rea aching and screwing down ghtly the cap.
4. Align assembled
fi
lter with the lugs on the cap end facing the front and back of
the head. Push the cap end into the head and then proceed to twist the as
‐
sembly clock
‐
wise 90 degrees to seal. ( A Quarter Turn). The
fi
lter is now
installed.
Turn on the cold water supply valve and open the faucet to
fl
ush air from the
system. Run water for 2
‐
3 minutes to pre
‐
condi on the
fi
lter. Close the
faucet. The system is now under pressure and can be inspected for leaks.
Repair any leak before con nuing use.