background image

 

ISQB1 Installation Guide - 2/13/2015 | SSS 

Example Part Number : 

ISQB1 

 

P  150  PS  G  BR 

 

YOUR PART NUMBER : 

 

 

 

 

 

 

 

 

 

 

Section   ——>  

2  3  4  5  6  7  8  9  10  11  12 

Options 

Series 

ISF1 

  Nonincindive ISF1* 

ISQB1 

  Intrinsically Safe ISQB1 

11  Pressure Unit 

 

  PS    PSI 

Inches Hg    IH 

MB    Millibars 

Inches H

2

O    IW 

BR    Bar 

mm H

2

O    MW 

KP    Kilopascal 

Kilograms/cm²    KG 

MP    Megapascal 

Torr*    TR 

MH    mm Hg 

   

Manifold Material 

B    Brass 

(Standard)

 

A    Aluminum 

Thread Type 

N    NPT 

(Standard)

 

P    BSPP 

Input Signal Range 

I    4 to 20 mADC 

Monitor Signal Range 

X    No Monitor 

Zero Offset 

N    0% Pressure Starts Below Atmosphere 

P    0% Pressure Starts Above Atmosphere 

Z    0% Pressure Starts at Zero 

(Typical)

 

Full Scale Pressure Type 

N    100% Pressure Ends Below Atmosphere 

P    100% Pressure Ends Above Atmosphere 

Z    100% Pressure Ends at Zero 

10  Full Scale Pressure  

  Must be less than or equal to 150 psig 

12  Pressure Unit of Measure 

A    Absolute Pressure 

G    Gage Pressure 

8  Zero Offset Pressure 

Typical is 0 

(blank)

*

 

If Greater than 30% of Full Scale 

Pressure (#9 below) Please Consult Factory.  

*Requires A for Pressure Unit of Measure 

*If Z for  Zero Offset (#7), please leave blank 

Sensor Type 

T    -14.7 to 150 psig 

13  Options 

R1  Rotate Connector 180 Degrees 

BR  Install Foot Bracket 

MOUNTING BRACKET 

Type 

Bracket 

P#

 

Wrap-Around 

QBT-01 

Please  Note: 

The  user  has  the  additional 

responsibility of supplying and or ensuring that the 

connector/cable  that  is  used  with  any  Proportion-

Air  ISQB  or  ISF1  series  FM  approved  product, 

meets  all  local  and  national  codes  for  intrinsically 

safe wiring.  

Summary of Contents for ISQB1

Page 1: ...urrent 100 Ω MECHANICAL PRESSURE RANGES Full Vacuum 150 psig 29 9 in HG Vac 10 3 Bar OUTPUT PRESSURE 0 100 of range FLOW RATE 0 80 SCFM 80 PSIG 23 L min 5 52 Bar Min CLOSED END VOLUME 1 in3 PORT SIZE 1 8 NPT FILTRATION RECOMMENDED 20 Micron included LINEARITY HYSTERESIS 0 15 F S BFSL REPEATABILITY 0 02 F S ACCURACY 0 2 F S PHYSICAL OPERATING TEMERPATURE 32 104 F 0 40 C T4 WEIGHT 2 5 lbs 1 1 Kg PRO...

Page 2: ... the media is hazardous classified the threaded exhaust port figure 1 should be vented into a safe area 5 Proceed with electrical connection TABLE 1 RATED PRESSURE FOR ISQB1 VALVES For valves ordered with MAX calibrated pressure of Max inlet pressure is Vacuum up to 10 psig 0 69 bar Consult factory 10 1 up to 30 psig 0 70 up to 2 bar 35 psig 2 4 bar 31 up to 100 psig 2 1 up to 7 bar 110 psig 7 6 b...

Page 3: ...3 ISQB1 Installation Guide 2 13 2015 SSS FIELD WIRING DRAWING ISQB 96026 2 General Barrier ...

Page 4: ...4 ISQB1 Installation Guide 2 13 2015 SSS FIELD WIRING DRAWING ISQB 96026 2 PEPPERL FUCHS KFD2 ...

Page 5: ...5 ISQB1 Installation Guide 2 13 2015 SSS FIELD WIRING DRAWING ISQB 96026 2 PEPPERL FUCHS Z728 KFD2 ...

Page 6: ...6 ISQB1 Installation Guide 2 13 2015 SSS FIELD WIRING DRAWING ISQB 96026 2 PHEONIX CONTACT MACX ...

Page 7: ...7 ISQB1 Installation Guide 2 13 2015 SSS FIELD WIRING DRAWING ISQB 96026 2 PEPPERL FUCHS KFD0 ...

Page 8: ...8 ISQB1 Installation Guide 2 13 2015 SSS FIELD WIRING DRAWING ISQB 96026 2 PEPPERL FUCHS Z728 ...

Page 9: ...ll Scale Pressure Type N 100 Pressure Ends Below Atmosphere P 100 Pressure Ends Above Atmosphere Z 100 Pressure Ends at Zero 10 Full Scale Pressure Must be less than or equal to 150 psig 12 Pressure Unit of Measure A Absolute Pressure G Gage Pressure 8 Zero Offset Pressure Typical is 0 blank If Greater than 30 of Full Scale Pressure 9 below Please Consult Factory Requires A for Pressure Unit of Me...

Page 10: ...g to the section titled Electrical Connections 2 Connect a precision pressure gage or pressure transducer to the OUTLET PORT of the ISQB1 NOTE There must be a closed volume of at least 1 in3 between the OUTLET PORT and the measuring device for the ISQB1 to be stable 3 Provide supply pressure to the INLET PORT of the ISQB1 See figure 1 Make sure supply pressure does not exceed the rating for the va...

Page 11: ...ges to equipment 1 PNEUMATIC CONNECTION All pipes pneumatic hose and tubing should be free of all contamination debris and chips prior to installation Flush pipes with compressed air to remove any loose particles 2 THREAD SEALANT To prevent product contamination thread tape is not recommended Instead a non migrating thread sealant is recommended for installation Apply sealant a couple threads from...

Reviews: