background image

 

11 

ISQB1 Installation Guide - 2/13/2015 | SSS 

Improper operation could result in serious injury to persons or 
loss of life! 

1.  PRODUCT COMPATIBILITY 

Proportion-Air, Inc. products and accessories are for use in 

industrial  pneumatic  applications  with  compressed  air 
media.  The  compatibility  of  the  equipment  is  the 
responsibility  of  the  end  user.  Product  performance  and 
safety are the responsibility of the person who determined 
the  compatibility  of  the  system.  Also,  this  person  is 
responsible for continuously reviewing the suitability of the 
products  specified  for  the  system,  referencing  the  latest 
catalog,  installation  manual,  Safety  Precautions  and  all 
materials related to the product. 

2.  EMERGENCY SHUTOFF 

Proportion, Inc. products cannot be used as an emergency 

shutoff.  A  redundant  safety  system  should  be  installed  in 
the system to prevent serious injury or loss of life. 

3.  EXPLOSIVE ATMOSPHERES 

Products  and  equipment  should  not  be  used  where 

harmful,  corrosive  or  explosive  materials  or  gases  are 
present.  Unless  certified,  Proportion-Air,  Inc.  products 
cannot  be  used  with  flammable  gases  or  in  hazardous 
environments. 

4.  AIR QUALITY 

Clean,  dry  air  is  not  required  for  Proportion-Air,  Inc. 

products.  However,  a  40  micron  particulate  filter  is 
recommended  to  prevent  solid  contamination  from 
entering the product. 

5.  TEMPERATURE 

Products  should  be  used  with  a  media  and  ambient 

environment  inside  of  the  specified  temperature  range  of 
32°F  to  158°F.  Consult  factory  for  expanded  temperature 
ranges. 

6.  OPERATION 

Only  trained  and  certified  personnel  should  operate 

electronic  and  pneumatic  machinery  and  equipment. 
Electronics  and  pneumatics  are  very  dangerous  when 
handled incorrectly. All industry standard safety guidelines 
should be observed. 

7.  SERVICE AND MAINTENANCE 

Service  and  maintenance  of  machinery  and  equipment 

should  only  be  handled  by  trained  and  experienced 
operators.  Inspection  should  only  be  performed  after 
safety has been confirmed. Ensure all supply pressure has 
been  exhausted  and  residual  energy  (compressed  gas, 
springs,  gravity,  etc.)  has  been  released  in  the  entire 
system  prior  to  removing  equipment  for  service  or 
maintenance. 

Warning

 

Improper operation could result in serious injury to persons or 
damages to equipment! 

1.  PNEUMATIC CONNECTION 

All pipes, pneumatic hose and tubing should be free of all 

contamination, debris and chips prior to installation. Flush 
pipes with compressed air to remove any loose particles. 

2.  THREAD SEALANT 

To  prevent  product  contamination,  thread  tape  is  not 

recommended. Instead, a non-migrating thread sealant is 
recommended  for  installation.  Apply  sealant  a  couple 
threads  from  the  end  of  the  pipe  thread  to  prevent 
contamination. 

3.  ELECTRICAL CONNECTION 

To  prevent  electronic  damage,  all  electrical  specifications 

should  be  reviewed  and  all  electrical  connections  should 
be verified prior to operation. 

Caution

 

Exemption from Liability 

Warranty 

1.  Proportion-Air,  Inc. 

is  exempted  from  any  damages 

resulting  from  any  operations  not  contained  within  the 
catalogs  and/or  instruction  manuals  and  operations 
outside the range of its product specifications.

 

2.  Proportion-Air, Inc. 

is exempted from any damage or loss 

whatsoever  caused  by  malfunctions  of  its  products  when 
combined with other devices or software.

 

3.  Proportion-Air, Inc. 

and its employees shall be exempted 

from any damage or loss resulting from earthquakes, fire, 
third 

person 

actions, 

accidents, 

intentional 

or 

unintentional  operator  error,  product  misapplication  or 
irregular operating conditions.

 

4.  Proportion-Air, Inc. 

and its employees shall be exempted 

from  any  damage  or  loss,  either  direct  or  indirect, 
including  consequential  damage  or  loss,  claims, 
proceedings,  demands,  costs,  expenses,  judgments, 
awards,  loss  of  profits  or  loss  of  chance  and  any  other 
liability  whatsoever  including  legal  expenses  and  costs, 
which  may  be  suffered  or  incurred,  whether  in  tort 
(including negligence),  contract, breach of statutory duty, 
equity or otherwise.

 

Proportion-Air,  Inc.  products  are  warranted  to  the  original 
purchaser only against defects in material or workmanship for 
one  (1)  year  from  the  date  of  manufacture.  The  extent  of 
Proportion-Air’s liability under this warranty is limited to repair 
or replacement of the defective unit at Proportion-Air’s option. 
Proportion-Air shall have no liability under this warranty where 
improper installation or filtration occurred. 

Safety Precautions

 

Please read all of the following Safety Precautions before installing or operating any Proportion-Air, Inc. equipment or accessories. 
To  confirm  safety,  be  sure  to  observe  ‘ISO  4414:  Pneumatic  Fluid  Power  -  General  rules  relating  to  systems’  and  other  safety 
practices. 

Summary of Contents for ISQB1

Page 1: ...urrent 100 Ω MECHANICAL PRESSURE RANGES Full Vacuum 150 psig 29 9 in HG Vac 10 3 Bar OUTPUT PRESSURE 0 100 of range FLOW RATE 0 80 SCFM 80 PSIG 23 L min 5 52 Bar Min CLOSED END VOLUME 1 in3 PORT SIZE 1 8 NPT FILTRATION RECOMMENDED 20 Micron included LINEARITY HYSTERESIS 0 15 F S BFSL REPEATABILITY 0 02 F S ACCURACY 0 2 F S PHYSICAL OPERATING TEMERPATURE 32 104 F 0 40 C T4 WEIGHT 2 5 lbs 1 1 Kg PRO...

Page 2: ... the media is hazardous classified the threaded exhaust port figure 1 should be vented into a safe area 5 Proceed with electrical connection TABLE 1 RATED PRESSURE FOR ISQB1 VALVES For valves ordered with MAX calibrated pressure of Max inlet pressure is Vacuum up to 10 psig 0 69 bar Consult factory 10 1 up to 30 psig 0 70 up to 2 bar 35 psig 2 4 bar 31 up to 100 psig 2 1 up to 7 bar 110 psig 7 6 b...

Page 3: ...3 ISQB1 Installation Guide 2 13 2015 SSS FIELD WIRING DRAWING ISQB 96026 2 General Barrier ...

Page 4: ...4 ISQB1 Installation Guide 2 13 2015 SSS FIELD WIRING DRAWING ISQB 96026 2 PEPPERL FUCHS KFD2 ...

Page 5: ...5 ISQB1 Installation Guide 2 13 2015 SSS FIELD WIRING DRAWING ISQB 96026 2 PEPPERL FUCHS Z728 KFD2 ...

Page 6: ...6 ISQB1 Installation Guide 2 13 2015 SSS FIELD WIRING DRAWING ISQB 96026 2 PHEONIX CONTACT MACX ...

Page 7: ...7 ISQB1 Installation Guide 2 13 2015 SSS FIELD WIRING DRAWING ISQB 96026 2 PEPPERL FUCHS KFD0 ...

Page 8: ...8 ISQB1 Installation Guide 2 13 2015 SSS FIELD WIRING DRAWING ISQB 96026 2 PEPPERL FUCHS Z728 ...

Page 9: ...ll Scale Pressure Type N 100 Pressure Ends Below Atmosphere P 100 Pressure Ends Above Atmosphere Z 100 Pressure Ends at Zero 10 Full Scale Pressure Must be less than or equal to 150 psig 12 Pressure Unit of Measure A Absolute Pressure G Gage Pressure 8 Zero Offset Pressure Typical is 0 blank If Greater than 30 of Full Scale Pressure 9 below Please Consult Factory Requires A for Pressure Unit of Me...

Page 10: ...g to the section titled Electrical Connections 2 Connect a precision pressure gage or pressure transducer to the OUTLET PORT of the ISQB1 NOTE There must be a closed volume of at least 1 in3 between the OUTLET PORT and the measuring device for the ISQB1 to be stable 3 Provide supply pressure to the INLET PORT of the ISQB1 See figure 1 Make sure supply pressure does not exceed the rating for the va...

Page 11: ...ges to equipment 1 PNEUMATIC CONNECTION All pipes pneumatic hose and tubing should be free of all contamination debris and chips prior to installation Flush pipes with compressed air to remove any loose particles 2 THREAD SEALANT To prevent product contamination thread tape is not recommended Instead a non migrating thread sealant is recommended for installation Apply sealant a couple threads from...

Reviews: