Promix-SM213

 

 

7

 

 

See  operating  voltage  range  in  5.2.  Avoid  application  of  a  higher  voltage  or 
excessive pulse duration.

 

 

Provide  a  reliable  electriccontact.  To  prevent  short-circuit,  insulate  places  of 
connection.

 

6.2 

CONNECTING PROCEDURE 

The lock operation is controlled by means of energizing and de-energizing. For this purpose, a 

controller  (control  board)  or  a  switch  (button)  is  generally  used.  The  controller  is  mounted  in 
accordance with its certificate. 

Connect the lock power wires adhering to the following polarity: 

Red (black with a red stripe) 

– positive pole of the power supply; 

Black 

– negative pole of the power supply; 

Application of voltage of reverse polarity does not provide the lock operability but does cause 

its failure. 

Example of the lock connection to the remote control system Promix-RDS. 

 

7.

 

SPECIAL ASPECTS OF INSTALLATION AND 
OPERATION

 

1)  The possibility of using of the locks for restriction of access to the premises and the place of 

installation  (outdoors  or  indoors)  are  determined  by  the 

installation  organization

  on  the 

basis  of  the  design  features  and  the  mounting  method,  room  criticality  level,  the  purpose  of 
the  access  restriction  regime  and  other  factors  (the  presence  of  security  providers,  video 
surveillance, etc.).  

2)  During  mounting  the  lock  and  the  locking  plate,  it  is  necessary  to  ensure  their  coaxial 

alignment within the catch free movement allowance. 

3)  NO lock may be mounted outdoors on condition that in winter it is closed (energized) for most 

time. This prevents freezing of lubricant in the mechanism due to release heat. 

NC locks are 

not intended for outdoor installation.

 

4)  The properly mounted lock provides the necessary free motion (play) of the door. If the free 

play  is  absent,  NC  lock  may 

fail  to  open

  when  energized,  and  NO  lock  may 

fail  to  close 

when energized (see section 8). 

5)  Operation of an installed NC lock should be tested only if the supply voltage can be applied 

thereto. 

6)  When using NC lock for restriction of access to rooms or in evacuation routes. Mounting of the 

lock deblocking mechanism  Promix-AD.KM.01 (delivered  separately) is obligatory, since it is 
necessary to provide exit for people in case of an emergency (e.g., fire). 

 

 

Lock 

 

Controller Promix-CR.RX 

 

Remote control 

Promix-CR.TX 

 

~220 V 

 

Summary of Contents for Promix-SM213

Page 1: ... audio and video intercoms code panels or other devices The lock design and mounting method allow them to be installed on practically any door types 2 LABELING The label stuck to the lock body contains the following information 1 Lock model 2 Patent number 3 Nominal supply voltage 4 Nominal consumed current 5 Date of manufacture and QCD mark 6 Identification number 7 Manufacturer s website For the...

Page 2: ... door lock As voltage is supplied for NO lock or voltage is removed for NC lock the lock catch is block and does not permit the door opening As voltage is removed for NO lock or supplied for NC lock the lock catch is deblocked and as the door is opened is folded into the lock body 5 TECHNICAL DATA 5 1 OPERATING CONDITIONS The environment of the lock must be explosion safe free of current conductin...

Page 3: ... of glazed frost 5 2 TECHNICAL DATA Modification Promix SM213 00 Promix SM213 01 Promix SM213 11 Promix SM213 10 Version normally opened normally closed DC supply voltage U V 12 2 24 2 12 2 Current consumed А 100 0 1 at 12V 35 at 24V 75 at 24V 160 0 1 at 12V Supply pulse duration not more than s not rated 120 at 23 26V 120 at 11 14V Minimum pause between pulses s not rated 120 Holding force not le...

Page 4: ...door leaf During mounting a clearance of 1 8 mm must be provided between the locking plate and the fastening plate of the lock Meeting this condition guarantees a door holding force of 300 kg and a smooth operation of the door without wedging up It is necessary to provide a clearance between the catch and the locking plate in the closed state of the door Example of the lock installation in a pipe ...

Page 5: ...Promix SM213 5 Example of the lock installation in the door frame of a wooden door Example of the lock installation in the leaf of a metal door Door Door Door Door Locking plate Locking plate ...

Page 6: ...ition The sticker covers an opening for water drain from the lock Remove white protective film from the locking plate and the lock Example of the lock installation in the door frame of a plastic door Example of the lock installation in the leaf of a wooden door For mounting the lock drill 4 holes 2 2 5 mm in diameter for self tapping screws and the locking plate 30 32 mm in diameter for lock mount...

Page 7: ... organization on the basis of the design features and the mounting method room criticality level the purpose of the access restriction regime and other factors the presence of security providers video surveillance etc 2 During mounting the lock and the locking plate it is necessary to ensure their coaxial alignment within the catch free movement allowance 3 NO lock may be mounted outdoors on condi...

Page 8: ...ition If this is impossible remove the locking plate from the door Fasten the locking plate to the door providing the required clearances NC lock does not close when supply voltage is applied NO lock does not open when supply voltage is applied Check the presence of required clearances between the catch and the locking plate see section 6 9 MAINTENANCE The lock Promix SM213 is lubricated by the ma...

Page 9: ... low DC supply voltage the products correspond to class III as per ГОСТ 12 2 007 0 75 and are electrically safe Fire safety of the locks is ensured by use of non combustible or hardly combustible materials and low supply voltage 12 DISPOSAL The product is not hazardous for human life and health or for the environment disposal after its service life is performed without taking any special measures ...

Page 10: ...ing the manufacturing date and QCD mark on the body was manufactured and accepted in compliance with Specifications ПШБА 304268 002 ТУ obligatory requirements of state standards and current technical documentation recognized as fit for operation and packed by ETC PROMIX LLC PROMIX Engineering and Technical Center LLC Russia 214030 Smolensk Krasninskoye sh 35 lit A Phone 4812 619 330 www promix cen...

Reviews: