** The valve spring is coated with CTFE (resistance similar to PTFE)
16.5 Ambient conditions
16.5.1 Ambient temperatures
Data
Value Unit
Storage and transport temperature
-10 ... +50 °C
Ambient temperature in operation (drive +
motor):
-10 ... +45 °C
16.5.2 Media temperatures
Data
Value Unit
Max. temperature, long-term at max. oper‐
ating pressure
50 °C
Max. temperature, for 15 min at max. 2 bar
100 °C
Minimum temperature
-10 °C
Data
Value Unit
Max. temperature long-term at max. oper‐
ating pressure
45 °C
Max. temperature for 15 min at max. 2 bar
60 °C
Minimum temperature
-10 °C
Data
Value Unit
Max. temperature long-term at max. oper‐
ating pressure
65 °C
Max. temperature for 15 min at max. 2 bar
100 °C
Minimum temperature
-10 °C
Data
Value Unit
Max. temperature long-term at max. oper‐
ating pressure
90 °C
Max. temperature for 15 min at max. 2 bar
120 °C
Minimum temperature
-10 °C
16.5.3 Air humidity
Data
Value Unit
Maximum air humidity*:
95 % relative
humidity
*non-condensing
Pump, compl.
PP liquid end
PC liquid end
PVT liquid end
SST liquid end
Air humidity
Technical data
88
Summary of Contents for S3Cb
Page 107: ...PTFE FDA No 21 CFR 177 1550 PVDF FDA No 21 CFR 177 2510 Wear parts for S3Cb 107 ...
Page 121: ...121 ...
Page 122: ...122 ...
Page 123: ...123 ...