9.3.4
‘Inputs/outputs’
‘Menu / Information
è
Settings
è
Inputs/outputs
è
...’
The
‘Inputs/outputs’
menu splits into the following sub-menus:
1 -
‘Auxiliary frequency’
2 -
‘Relay1’
(optional)
3 -
‘Relay2’
(optional)
4 -
‘mA-Output’
(optional)
6 -
‘Flow monitor’
(only if connected)
5 -
‘Diaphragm rupture’
(only if connected)
9.3.4.1
‘Auxiliary frequency’
‘Menu / Information
è
Settings
è
Inputs/outputs
è
Auxiliary frequency
è
...’
The programmable function
‘Auxiliary frequency’
facilitates the switchover
to an auxiliary stroke rate, which can be set in the
‘Auxiliary frequency’
menu.
It can be activated via the "External control" terminal. If the
‘Auxiliary
frequency’
is present, then the identifier “AUX” appears on the LCD
screen.
Refer to the "Hierarchy of Operating Modes, Functions and Fault Statuses"
for the order of the various operating modes, functions and fault statuses.
9.3.4.2
‘Relay1 (optional)’
‘Menu / Information
è
Settings
è
Inputs/outputs
è
Relay1
è
...’
The setting options for the ‘Relay’ function only exist if a
relay is fitted.
Tab. 6: Relay, physical and pre-set to ...
Identity code specification
Relay, physical
Pre-set to ...
1
1 x changeover contact 230 V – 8 A
Fault indicating relay, N/C
3
2 x N/O 24 V – 100 mA
Fault indicating relay, N/C, and pacing
relay
8
1 x N/O 24 V – 100 mA, + 4...20 mA
output
Fault indicating relay, N/C
Set up /
‘Menu’
53