Identity code
specification
Phase, protection
Rated voltage
Mains supply fre‐
quency
Rated output
HP2a
Remarks
P2
3 ph, II2GEEX‐
dIICT4
250-280 V /
440-480 V
60 Hz
0.37 kW
with PTC, speed
control range 1:5
R/Z
3-phase, IP 55
230 V / 400 V
50/60 Hz
0.37 kW
with PTC, speed
control range 1:20
with external fan 1-
ph 230 V; 50/60 Hz
V0
1 ph AC, IP 55
230 V ±10%
50/60 Hz
0.37 kW
Variable speed
motor with inte‐
grated frequency
converter
V2
3 ph, II2GEEX‐
dIICT4
400 V ±10%
50/60 Hz
0.55 kW
EX variable speed
motor with inte‐
grated frequency
converter.
HP3
Identity code
specification
Phase, protection
Rated voltage
Mains supply fre‐
quency
Rated output
Remarks
S
3-phase, IP 55
220-240 V /
380-420 V
50 Hz
0.75 kW
250-280 V /
440-480 V
60 Hz
0.75 kW
L1
3 ph, II2GEEXeIIT3
220-240 V /
380-420 V
50 Hz
0.75 kW
L2
3 ph, II2GEEX‐
dIICT4
220-240 V /
380-420 V
50 Hz
0.75 kW
with PTC, speed
control range 1:5
P1
3 ph, II2GEEXeIIT3
250-280 V /
440-480 V
60 Hz
0.75 kW
P2
3 ph, II2GEEX‐
dIICT4
250-280 V /
440-480 V
60 Hz
0.75 kW
with PTC, speed
control range 1:5
R/Z
3-phase, IP 55
230 V / 400 V
50/60 Hz
0.75 kW
with PTC, speed
control range 1:20
with external fan 1-
ph 230 V; 50/60 Hz
V0
1 ph AC, IP 55
230 V ±10%
50/60 Hz
0.75 kW
Variable speed
motor with inte‐
grated frequency
converter
V2
3 ph, II2GEEX‐
dIICT4
400 V ±10%
50/60 Hz
EX variable speed
motor with inte‐
grated frequency
converter.
Motor data sheets, special motors, special motor flanges,
external fan, temperature monitoring
–
For further information for the motor with identity code
specification "S", refer to the motor data sheet in the
Appendix. Motor data sheets can be requested for all
other motors.
–
For other motors than those with identity code specifica‐
tion "S": Pay special attention to the operating instruc‐
tions for the motors.
–
Special motors or special motor flanges are possible on
request.
Technical data
70