13
Technical data
WARNING!
Risk of personal injuries
Please observe the ”Supplement for modified version“ at the
end of the chapter!
It replaces and supplements the technical data!
13.1 Performance data
Type
Minimum pump capacity at maximum
back pressure
Maximum
stroke rate
Suction
lift
Permissible
priming pres‐
sure, suction
side
Connector size
bar
l/h
ml/stroke
Strokes/min
m WS
bar
G-DN
100003*
100
3
0.8
60
3
5
Rp 3/8" - 10
100006*
100
6
0.8
125
3
5
Rp 3/8" - 10
100007*
100
7
0.8
150
3
5
Rp 3/8" - 10
100009*
100
9
0.8
187
3
5
Rp 3/8" - 10
100010*
100
10
0.8
212
3
5
Rp 3/8" - 10
064007
64
7
2.0
60
3
5
G 3/4" - 10
064015
64
15
2.0
125
3
5
G 3/4" - 10
064018
64
18
2.0
150
3
5
G 3/4" - 10
064022
64
22
2.0
187
3
5
G 3/4" - 10
064025
64
25
2.0
212
3
5
G 3/4" - 10
025019
25
19
5.3
60
3
5
G 3/4" - 10 **
025040
25
40
5.3
125
3
5
G 3/4" - 10 **
025048
25
48
5.3
150
3
5
G 3/4" - 10 **
025060
25
60
5.3
187
3
5
G 3/4" - 10 **
025068
25
68
5.3
212
3
5
G 3/4" - 10 **
* Material version SST / HCT with double ball valve
Alternative double ball valve SST with RP 3/8
** HV design G1-DN 15
Maximum back pressure for liquid ends in material version PVT: 25 bar!
The metering capacity can deviate from the details above with the HV ver‐
sion.
All figures refer to water at 20 °C.
Priming lift / priming pressure (dry) determined for empty suction line and
empty liquid end and as well as clean and moistened valves (the figures
are lower with valve springs).
The suction lift / suction pressure applies to filled suction lines and filled
liquid end - when installed correctly.
Only for "M - modified" design:
HP2a at 50 Hz operation
Technical data
63