12
Technical data
Performance data
Data
Value Unit
Measuring range, pulsing, type 05:
0.1... 13 L/h
Measuring range, pulsing, type 08:
0.6... 80 L/h
Smallest measurable lifting volume, pulsing approx.
0.03 mL/stroke
Accuracy over at least 100 strokes:
± 2 %*
* relative to the measured value
Electrical data
Data
Value Unit
Stroke feedback, output**:
1 Contact/stroke
Frequency output**:
< 10 kHz
Current output, max. load:
400 Ω
Protective system:
IP 65
Supply voltage:
100...230 V AC
Mains supply frequency:
50/60 Hz
** open collector
Media requirements
Material compatibility with: PVDF, sealing material
Data
Value Unit
Medium pressure:
0...16 bar
Medium temperature:
-10...+45 °C
Dynamic viscosity (η):
0.5...2000 mPas
Sound pressure level:
1000 ... 2500 m/s
Technical data