Flow direction
The flow direction through the device goes
from the bottom to the top.
Injection valves, back pressure
valves, relief valves
Injection valves, back pressure valves or
relief valves must not have any effect on
the measurement.
Relief valves
It is best to install a relief valve before the
flow meter, so that the displayed flow or
flow volume actually corresponds to the
value which is being metered into the
system if the relief valve triggers.
Hydraulic Dampers
Hydraulic dampers, like accumulators,
inline dampers or bladder accumulators /
diaphragm accumulators must not have
any effect on the measurement.
A zero flow must be available.
The damping must not push the flow mean
value beneath the measurement threshold.
Installing the hosing:
1.
Cut off the ends of the hoses (6) so that
they are straight.
2.
Unscrew the union nut (5) and push
over the hose together with the clamp
ring (4).
3.
Push the hose end (6) up to the stop
over the nozzle (3).
4.
Tighten the union nut (5).
5.
Pull on the hose (6) and tighten up the
union nut (5).
1
3
2
4
5
6
P_MAZ_0041_SW
Fig. 2: Installing the hose line
1
Connector
2
Seal
3
Nozzle
4
Clamp ring
5
Union nut
6
Hose
Assembly and installation
16