Operating errors, help, troubleshooting
* • check if function plug is plugged in and if
cable is correctly connected
• mini-contact has been altered re-adjust
• check position of stop valves in bypass.
** • check solenoid valve “water feed”
• check level monitoring device float “EMPTY”
• check water feeding
• pc-board, check signal
1
when using turbine flow meter
Table 21: Error messages
malfunction
message
effekt
delay
red
clear
warn.
Alarm
corrective
LED
relay
relay
action
flow monitor
Acid pump
metering stops
after 8
flashes
man.
on
on
bleed or set
acid pump
ERROR
strokes
monitoring element
flow monitor
Chlorite pump
metering stops
after 8
flashes
man.
on
on
bleed or set
chlorite pump
ERROR
strokes
monitoring element
flow monitor
Water pump
metering stops
after 8
flashes
man.
on
on
bleed or set
water pump
ERROR
strokes
monitoring element
acid level
acid level
metering
on
man.
on
change
initial warning
low
continues
container
chlorite level
chlorite level
metering
on
man.
on
change
initial warning
low
continues
container
acid level
acid tank
metering stops
flashes
man.
on
change
EMPTY
container
chlorite level
chlorite tank
metering stops
flashes
man.
on
on
change
EMPTY
container
level monitoring
Water tank!
metering stops
on
man.
on
on
** find
device “EMPTY”
cause
level monitoring
Water tank!
on
water feeding
divice “FULL”
too long
bypass flow
bypass
metering stops
0.7 sec.
on
auto.
on
* find
insufficient
FAULT
cause
bypass flow less
bypass
metering stops
on
auto.
on
* find
than main water flow
1
FAULT
cause
pc-board fault
flow input
metering stops
5 sec.
flashes
man.
on
on
check pc-board
or 3.7 mA >
FAULT
check signal
current signal > 23 mA
pc-board fault
Rem.ctr.anlg.
metering stops
5 sec.
flashes
man.
on
on
check pc-board
or 3.7 mA >
FLT
check signal
current signal > 23 mA
pc-board fault
Rem.ctr.anlg.
metering stops
5 sec.
flashes
man.
on
on
check pc-board
FLT
pc-board fault
Dos.ctr.inp.
metering stops
5 sec.
flashes
man.
on
on
check pc-board
FLT
pc-board fault
Byp.ctr.inp.
metering stops
5 sec.
flashes
man.
on
on
check pc-board
FLT
supply voltage
-
metering stops
-
off
off
an
find
vailure
cause