USER'S MANUAL FP-2b

Page 10

Janvier 2001

3.2  Specific safety rules

 

When measuring resistances take care that circuit under test

is not powered.

 

When measuring currents disconnect the power supply of the

circuit under test before inserting the multimeter in series.

 

When measuring currents, be sure  that  points  under test  do

not exceed the maximum voltage.

 

Keep measuring leads in good condition.

 

Between measurements higher than 10 A which extend near

to  the  maximum  time  specified,  keep  waiting  times  of  about

10 minutes.

 

Before  rotating the  range  selector,  disconnect  the  test  leads

from the circuit under test.

 

When  measuring  capacities,  be  sure  capacitors  are

previously discharged.

 

Disconnect  the  test  leads  before  inserting  transistors  or

capacitors in their respective sockets.

Summary of Contents for FP-2b

Page 1: ...DIGITAL MULTIMETER FP 2b USER S MANUAL 99 Washington Street Melrose MA 02176 800 517 8431 TestEquipmentDepot com...

Page 2: ......

Page 3: ...inly SAFETY RULES paragraph The symbol on the equipment means SEE INSTRUCTION MANUAL In this manual may also appear as a Caution or Warning symbol WARNING AND CAUTION statements may appear in this man...

Page 4: ......

Page 5: ...SPECIFICATIONS 3 3 SAFETY RULES 9 3 1 General safety rules 9 3 2 Specific safety rules 10 4 OPERATING INSTRUCTIONS 11 5 MAINTENANCE 13 5 1 Shipment instructions 13 5 2 Battery replacement 13 5 3 Repla...

Page 6: ......

Page 7: ...to 100 V Automatic overrange indication by means of 1 on the display Automatic polarity indication on the DC range Resistance measurement from 0 1 up to 200 M Capacity measurement from 1 pF up to 20 F...

Page 8: ...USER S MANUAL FP 2b Page 2 Janvier 2001...

Page 9: ...to 40 C Storage temperature 10 C to 50 C Power supply 9V battery 6F22 Dimensions W 88 x H 170 x D 38 mm Weight 340 g battery included Included accessories Test leads PP 008 Case DC 231 NOTE Accuracy...

Page 10: ...ncy range 40 Hz to 1000 Hz Overload protection 700 V AC sine wave signal Indication Average calibrated in RMS of sine wave DC Current Range Resolution Accuracy 2 mA 1 A 20 mA 10 A 0 8 reading 1 dig 20...

Page 11: ...rrent 10 A in continuous mode 20 A 15 s maximum Response Average calibrated in rms of sine wave Resistance Range Resolution Accuracy 200 0 1 0 8 reading 3 dig 2 k 1 20 k 10 200 k 100 2 M 1 k 0 8 readi...

Page 12: ...nF 2 F 10 nF 4 reading 3 dig Frequency test Range Resolution Accuracy 2 kHz 1 Hz 2 reading 5 dig 20 kHz 10 Hz 1 5 reading 5 dig Overload protection 250 V DC AC rms Sensitivity 200 mV AC rms Maximum in...

Page 13: ...USER S MANUAL FP 2b Janvier 2001 Page 7 Continuity test Range Threshold 50 Overload protection 250 V DC AC rms Transistors test Range hFE Readout hFE DC gain Base current 10 A Vce voltage 3 2 V...

Page 14: ...USER S MANUAL FP 2b Page 8 Janvier 2001...

Page 15: ...to ensure safety Test leads Use this instrument under the specified environmental conditions The user is only authorized to carry out the following maintenance operations Battery replacement Fuse rep...

Page 16: ...be sure that points under test do not exceed the maximum voltage Keep measuring leads in good condition Between measurements higher than 10 A which extend near to the maximum time specified keep wait...

Page 17: ...est leads to the measurement points For currents higher than 200 mA connect the test leads to the 10 A red and COM black jacks Measuring resistance Connect the black test lead to the COM jack and the...

Page 18: ...s of the circuit under testing If continuity exists i e resistance less than about 50 built in buzzer will sound Testing transistor Set the rotary selector at hFE position and verify if transistor is...

Page 19: ...lephone number purchase receipt in the case of warranty period and problem description Freights will be charged to the client 5 2 Battery replacement When the symbol appears on the LCD display it indi...

Page 20: ...e it with a new one of the following characteristics 200 mA F 250 V Place and fix the lid again 5 4 Cleaning recommendations The cover should be cleaned by means of a light solution of detergent and w...