background image

Setup and Operation

NOTE: This LED configuration indicates that the charger is functioning normally and does not
need any further attention.  If the RED “Fault” LED illuminates ,or any of the “Charger Conditions”
LED’s are illuminated, consult the Troubleshooting section of this manual.

OPERATIONAL NOTE: Your ProNauticP Charger has built in safety features that can cause
the unit to shut down if it senses out of parameter operations such as over-voltage and
high temperatures. See the Troubleshooting section of this manual for more details in the
event this occurs.

Optional Remote Display

When the optional remote is installed, it will display the current status of the charger along
with the voltage and amperage.

1. The blue LED is illuminated when the power is ON

2. BACKLIGHT can be set to ON or OFF by toggling the BACKLIGHT button, default is ON

3. ALARM can be silenced or audible by toggling the ALARM button, default is audible

15

Optional Remote

Power LED

blue

indicates power is ON

Fault LED

red

indicates a fault

Backlight button

toggle between ON and OFF by pushing repeatedly, default is ON

Alarm Button

toggle between silent and audible by pushing repeatedly, default is audible

Setup

selects both “scrolling mode” and activates chosen feature

Enter

(see optional remote programming section
controls for scrolling in “scroll mode”

 

16

Setup and Operation

On-Unit LED Indicators and Digital Displays

Feature

Color

Function

AC power

Blue

AC power applied

Auto temp control

Green

Temperature control feature (cooling fan)
active, red flashing if high-temp causes
unit shutdown (see troubleshooting)

Active PFC

Green

ON when AC power light is on, indicating
power factor correction is functioning

Variable speed

Amber

Indicates speed of fan during auto temp control

cooling (1,2,3)

(feature syandard on 20amp and above units).

Charger Mode

Charge

Green

Charger is in charge mode, actively charging
the battery(s) (bulk charge)

Conditioning

Green

The unit is in absorption charge mode

Ready

Green

The charger is in float charge mode

Equalization

Red

Equalization charge has been initiated by user
(flooded batteries ONLY, see setup)

Self test

Blue

Charger is performing a system check
initiated by start-up or manually

OK

Green

Indicates successful self test

Fault

Red

Indicates a fault (see troubleshooting)

The ProNauticP is a fully automatic battery charger. The features listed below can be selected
during initial set-up (see Programming section) or upon a new battery installation. Normal
operation does not require any intervention from the user. See the Maintenance section for
information on periodic checks.

1

2

3

3

Battery Profiles

Charger Conditions

Charger Mode

Ready

Conditioning

Charging

AC Power

Auto Temp Control

Active PFC

Amps

Volts

SYSTEM DC OUTPUT  LEVELS

Variable Speed Cooling

Self Test

Fault

OK

Standby

AUTO CONSERVATION MODES

100%

0%

Battery Health Program

Equalization

Charger Output

SETUP
ENTER

SELF TEST: Hold all keys 5 seconds

WARNING: HIGH VOLTAGE
ATTENTION : HAUTE TENSION

WARNING: LOW VOLTAGE
ATTENTION : BASSE TENSION

AVOID SERIOUS INJURY OR DEATH FROM ELECTRICAL SHOCK. BEFORE OPENING
TURN OFF AC SUPPLY POWER. DO NOT EXPOSE TO RAIN OR SPRAY.
CHOC ELECTRIQUES PEUVENT PROVOQUER LA MORT OU DE SERIEUSE BLESSURES.
AVANT D'OUVRIR LA BOITE, COUPER LE COURANT. NE PAS EXPOSER AUX INTEMPÉRIES.

ELECTRICAL BURN AND SPARK HAZARD. BEFORE OPENING
DISCONNECT CHARGER CONNECTIONS AT BATTERIES.
(DANGER DE BRULURES ELECTRIQUE ET ETINCELLES). AVANT D'OUVRIR LA
BOITE DECONNECTER LES CONNECTIONS ENTRE CHARGEUR ET BATTERIE.

P

reset-1

P

reset-2

Flooded

Sealed

AGM

GEL

LiFePO4-Lithium

Calcium/Custom

Reverse Polarity

DC Volts Low

DC Volts High

Charger High Temp

Check Fan

Digital

Pro

Mar

Performance Charging

Summary of Contents for ProNautic 1210P

Page 1: ...40 Amps 3 Banks 12 ProNautic1250P 63150 50 Amps 3 Banks 12 ProNautic1260P 63160 60 Amps 3 Banks 12 ProNautic2420P 63170 20 Amps 3 Banks 24 ProNautic2430P 63180 30 Amps 3 Banks 24 Professional Mariner...

Page 2: ...s 3 Percentage of Outputs Used 8 AC Side Terminations 4 Faults 9 Voltage Out Display 5 Charging Profile Selected 10 ABYC Recommended Bonding Stud 2 Introduction 20 8 7 6 4 3 2 1 5 9 10 1 2 3 3 Battery...

Page 3: ...NG YOUR PRONAUTIC P SERIES CHARGER This manual is written to assist in the installation of your new ProNauticP Series Charger however since this is a permanent AC and DC hardwired installation ProMari...

Page 4: ...Turningoffcontrolswillnotreducethisrisk WARNINGAVOIDSERIOUSINJURYORDEATHFROMFIRE EXPLOSIONORELECTRICALSHOCK Make connection in an open atmosphere free of explosive fumes Make connection in a secure m...

Page 5: ...cabling used is dependent upon the proximity to the battery s being charged When deciding on a location this should be a consideration Consult the DC cable size table further on in this manual when pl...

Page 6: ...WG ProNautic2420P 15 Amp 10 Amp 12 AWG ProNautic2430P 15 Amp 10 Amp 10 AWG AC Breaker Sizing 2 Connections Using ring or captive spade connections and the proper crimping tool attach the Line Neutral...

Page 7: ...ach the phone style plug into the charger port labeled BAT SENSE Note Once the temperature sensor is connected the charger will adjust its charge based on the batteries temperature This is known as th...

Page 8: ...test was initiated OK green following successful self test Ready green based on state of charge Charge green based on state of charge Conditioning green based on state of charge 13 Setup and Operatio...

Page 9: ...speed of fan during auto temp control cooling 1 2 3 feature syandard on 20amp and above units Charger Mode Charge Green Charger is in charge mode actively charging the battery s bulk charge Conditioni...

Page 10: ...peration Battery Types Lithium Battery Caution There are many types of Lithium batteries with various charging requirements Improper charging can result in damage to the battery or catastrophic failur...

Page 11: ...ontact ProMariner for service options Auto Temp Control Red flashing High temp causes unit shutdown See charger high temp above Note Installation is permitted in an environment of 45 C 113 F and may r...

Page 12: ...nections both at battery and the ProNauticP Charger for corrosion clean and reconnect immediately upon signs of corrosion Per manufacturer s instructions check and top off batteries with distilled wat...

Page 13: ...Dimensions Inches mm 7 3 4 198mm ProNautic12 60P Power Factor Corrected Global AC Input 5 1 8 130 mm 3 5 8 93 mm 3 5 8 93 mm 12 3 8 315 mm 8 1 2 215 mm 3 1 2 90 mm Dimensions 24 Optional Remote Dimen...

Page 14: ...er than the L N G AC Input 12V Battery Battery Bank Typical 3 Bank12 Volt DC Common Ground Installation Typical Wiring Configurations 26 1 2 3 3 Battery Profiles Charger Conditions Charger Mode Ready...

Page 15: ...below Professional Mariner will make its best effort to repair or replace the product if found defective within the terms of the warranty within 30 days after return of the product to the company Pro...

Page 16: ...Notes Notes...

Reviews: