Installation 

Warnings 

      

 

SAFETY FIRST- 

Follow all precautions in the important safety instructions section in this manual. Pay close attention 
to the DANGER, WARNING and CAUTION boxes within this manual and labeled on the unit. 

 

WARNING: 
ELECTRICAL POTENTIALS HAZARDOUS TO HUMAN LIFE CAN EXIST WITHIN THIS EQUIPMENT 
WHEN ENERGIZED. DISCONNECT ALL INPUT POWER BEFORE OPENING CASE OR TOUCHING 
INTERNAL PARTS. USE PROPER LOCK-OUT / TAG-OUT PROCEDURES. 
THE INFORMATION CONTAINED HEREIN MAY NOT COVER ALL VARIATIONS IN EQUIPMENT OR 
PROVIDE FOR ALL CONTINGENCIES WHICH MAY BE MET DURING INSTALLATION, OPERATION 
AND MAINTENANCE. 

 

INSPECTION UPON RECEIVING 

Transformers should be carefully inspected upon receipt to ensure that no damage has occurred 
during shipment. Any damage should be reported at once and a claim placed against the 
transportation company. 

 

INSPECTION DURING INSTALLATION 

The transformer should be carefully inspected for any damage due to handling after receipt. The 
nameplate rating on the unit should be checked against the job specifications to ensure installation of 
the correct transformer. The transformer should be connected only as described on the label found 
on the inside of the transformer cover or as shown in this manual.  

 

Taps should be adjusted, if necessary, to match the available line voltage. Any bolted electrical 
connections, including taps, should be checked and tightened since fasteners may have loosened 
during shipment.  

 

Warning- Fire Hazard 

Primary and secondary over-current protection and conductor sizing must be in accordance with 
ABYC recommendations.  

 

Warning- Fire Hazard 

Do not store any equipment on or next to transformer; The ProSafe Isolation Transformer is designed 
to operate hot and must have free air flow to prevent over heating or damaging of neighboring 
objects. 

 

Warning- Shock Hazard 

In-water and on board shock hazard; The ProSafe Isolation Transformer must be connected in 
accordance with these installation instructions. 

 

Warning- Electrical Shock and Fire Hazard 

The ProSafe isolation transformer is designed for installation inside an engine room or similar 
compartment inside the boat. Assure that the location of installation will not be subject to rain, snow, 
excessive moisture or excessive heat.

 

 

Warning- Installation Precaution 

Boat wiring should only be done by qualified personnel as it can 

cause shock, corrosion and other hazards if not done properly. For more information on this subject 
contact the 

American Boat and Yacht Council

 (ABYC). 

Summary of Contents for 411-SA02-036

Page 1: ... this manual for proper installation and operation instructions of this device It is essential for the safety of your boating family and other boating families around you that this product be properly installed For all Product Installation or Service questions please call ProMariner direct at 1 800 824 0524 Eastern Time 8 30am 5 00pm ...

Page 2: ...duct Overview pages 1 2 Introduction page 3 Theory of Operation page 4 Installation Warnings page 5 Installation Operating Safety page 6 Wiring Diagrams pages 7 17 Maintenance pages 18 19 Customer Service and Warranty page 20 ...

Page 3: ...stand without breakdown a high potential test of 4000 volts AC 60Hz for one minute applied between the shield and all other components such as windings core and outside enclosure 11 9 1 2 A separate insulated wire lead or terminal identified as the shield connection is to be solidly connected only to the shield and brought out for external connection and shall be equal to or greater than the aggre...

Page 4: ...rmer the shield can bear the fault current of a properly sized shore supply circuit breaker long enough for the breaker to trip Properly installed the ProSafe Isolation Transformer will electrically isolate AC shore power from the boat s AC power system reducing galvanic corrosion due to a direct AC shore power connection This occurs because grounding one leg of the transformer secondary on board ...

Page 5: ... described on the label found on the inside of the transformer cover or as shown in this manual Taps should be adjusted if necessary to match the available line voltage Any bolted electrical connections including taps should be checked and tightened since fasteners may have loosened during shipment Warning Fire Hazard Primary and secondary over current protection and conductor sizing must be in ac...

Page 6: ...y area where sound is objectionable TRANSFORMER LIFE Transformer life is dependent upon the thermal degradation of the insulation system which in turn is dependent upon the winding temperature and duration of operation at that Temperature Factors which affect transformer life are line voltage load current load cycle ambient temperature and other environmental conditions such as moisture corrosive ...

Page 7: ...7 ...

Page 8: ...8 ...

Page 9: ...9 ...

Page 10: ...10 ...

Page 11: ...11 ...

Page 12: ...12 ...

Page 13: ...13 ...

Page 14: ...14 ...

Page 15: ...15 ...

Page 16: ...16 ...

Page 17: ...17 ...

Page 18: ...HIS MANUAL FOLLOWING THESE PROCEDURES WILL RESULT IN SATISFACTORY PERFORMANCE WHEREAS DISREGARDING THEM CAN VOID THE WARRANTY The inspection for loose connections condition of terminal board overheating rust paint deterioration and general condition of the unit by a qualified service technician is recommended Corrective measures should be taken if necessary If there is a problem with your ProSafe ...

Page 19: ...imary and secondary circuits 2 Remove all fuses from the power source Additionally trip circuit breakers and take appropriate action to prevent the accidental resetting of the circuit breakers 3 Short out transformer secondaries before connecting and disconnecting equipment 4 To prevent potentially lethal high voltage current levels always connect a load to the secondary side of the transformer be...

Page 20: ...AL DAMAGES OF ANY KIND Some states do not allow the exclusion or limitation of consequential damages so the above limitations may not apply to you This warranty is made in lieu of all other obligations or liabilities on the part of Professional Mariner Professional Mariner neither assumes nor authorizes any person for any obligation or liability in connection with the sale of this product To make ...

Page 21: ...argers Battery Maintainers AC Plug Holders Battery Isolators ProSport Cup Holder Inverters Pro Inverters DC to AC Inverters Advanced Regulators Corrosion Control Products Waterproof Marine Binoculars Marine CCTV Color Camera Equipment Gold Plated Fuses and Holders A Complete Selection of Panel Meters and Shunts A Complete Line of Hand Held Test Meters Online Technical Support and Service Support V...

Reviews: