TR515 User’s Manual
24
Phase 1 begins immediately upon entering the Test mode. The LED
displays “TEST” at this time:
A number of errors can occur during this portion of the test: All errors are
displayed in the “ERR
x
” format, where
x
is the error number, for example:
All possible errors are listed in the table below:
Err1
SRAM test failure
Err2
RTC test failure
Err3
FLASH test failure
Upon successful completion of the automated tests, the TR515 will beep
and display “b1-5” (OUT LED will be switched on):
This means that the manual test phase has commenced. This phase
consists of three steps: OUT button test, IN button test, and reader test. Each
step must be repeated five times.
Press the OUT button and notice that “b1-5” changes to “b1-4”, “b1-3”, etc.
When you press the OUT button for the fifth time, the display will change to
“b2-5” and the IN LED will be switched on. Press the IN button five times to
finish this test step.
The display reads “rd-5” at the beginning of the reader test. Read any ID-
card five times to pass this portion of the test.
When all manual tests are finished, the TR515 will generate a long beep
and display “PASS”:
This indicates that the test sequence has been completed successfully. You
can still continue testing the buttons and the reader at this point. The TR515 will
behave as if in the Normal Mode of operation, but no records will be added to
the database.