Set new machine number (‘I’, 49H)
Possible error codes: 04, 07
Command I
NN
Reply A
NN-
machine number in Hex form (00H-FFH), 00 should never be used on a
multi-terminal network because this is a universal number (see D-command
description for details).
This command is used to assign a new machine number to the terminal.
Machine numbers provide a way to distinguish between the terminals on a
multi-terminal network. See D-command description for more details.
Get machine number (‘Y’, 59H)
Possible error codes: 07
Command Y
Reply A
NN
NN-
machine number in Hex form (00H-FFH)
This command is used to retrieve the terminal’s machine number. Machine
numbers provide a way to distinguish between the terminals on a multi-terminal
network. See D-command description for more details.
Set date/time (‘S’, 53H)
Possible error codes: 04, 07
Command S
YYYYMMDDhhmmss
Reply A
YYYY
-year,
MM
- month,
DD
-date,
hh
-hour,
mm
-minutes,
ss
- seconds
This command is used to set the TR515’s internal clock. Date/time supplied
must be valid. Incorrect data (like 31
st
of February) will be rejected (error 04).
Summary of Contents for TR515
Page 1: ...TR515 Time Recorder V1 00...