MF7xx
PROMAG
REV.C
6
Mifare Reader Utility
1. Mifare
Settings:
MAD-AID: (Default=4703)
MAD Application Identifier number is authorized and assigned by Mifare.net upon the customer’s request
for registered Application Identifier in a mifare® application open system (AID: 0000h~FFFFh).
Or it is also possible for the user to define the AID himself for the application in user defined closed
system without registering into MAD group. According to the AID, MF7XX can find and read the
corresponding sector on the MAD card.
Non-MAD Sector: (Default =0)
When the card is Non-MAD format, MF7XX will only read the “Non-MAD Sector”.
(1K Card Sector: 0~15, 4K Card Sector:0~39). For the Non-MAD application, user can freely define the
Sector.
App Key (KEY_A): (Default=FFFFFFFFFFFF)
App Key must be the same as the KEY_A of the card issued. This means MF7XX only can read the sector
data on the card with the same KEY_A.
Encrypt: (Default=None)
Fraud prevention, Select Encrypt Mode (None, Encrypt 1, Encrypt 2, Encrypt 3, Encrypt 4, Encrypt 5) to
protected your card data. (Remark: Encrypt mode must to work together with the same encrypt mode of
“Mifare Card Issuer” software.)