MF7xx
PROMAG
REV.C
13
6. RS232
Setting:
Baudrate
can be set 2400bps~57600bps (Default=19200bps)
Data Sequence
can be set “LSB” first (Default) and “MSB” first.
Package
2
is to set the output data packet to include Header, Reader ID, Data Length, CR, LF and Trailer.
(Header:00h~FFh, Trailer : 00h~FFh). (Default = None included)
Output Format
can be “Binary” or “Hex String” for output format.
Note:
(1).Wiegand output data packet with Reader ID:
(2).RS232 output data packet with Header, Reader ID and Trailer:
Header
Reader ID (LSB) Data Bytes (MSB)
Trailer
(3).ABA-TK2 with Reader ID:
Remark:
MF7XX all configuration items are write only, so any users can not read the configuration items from MF7XX
to get the App Key, that is very important to protect your App Key and all configuration items.
Standard Parity(
Even
) Reader ID
(MSB) Data Bits (LSB)
Parity(
Odd
)
Reverse
Parity(
Odd
)
Reader ID
(LSB) Data Bits (MSB)
Parity(
Even
)
MSB First
SS
Reader ID
(MSB) Digital Code (LSB)
ES
LRC
LSB First
SS
Reader ID
(LSB) Digital Code (MSB)
ES
LRC