©Prolyte Products Group 2009
Prolyte has made every effort to ensure the accuracy of this manual. No liability will be accepted for errors. Prolyte reserves the right to change or alter their products or
manuals without prior notice. No part of this manual may be reproduced in any form or by any means without prior written permission.
Prolyte Products Group – Phone +31 (0)594 85 15 15 Fax: + 31 (0)594 85 15 16 www.prolyte.com
pages 4 of 18
USER MANUAL PLE-30
DIRECT CONTROLLED HOIST
PiCKLE FOR LOW VOLTAgE CONTROL
Wire
Colour / EU
Function
Pin
L1
Brown
110Vac
1
L2
Grey
Up
2
L3
Black
Down
3
PE / ground
Yellow/Green
GND
BRAKE iNS / BRAKE OUTS
Wire
Colour / EU
Pin
MOTOR 1
L1
Brown
1
L2
Black
2
L3
Black
3
GND
Yellow/Green
4
MOTOR 2
L1
Brown
5
L2
Black
6
L3
Black
7
GND
Yellow/Green
8
MOTOR 3
L1
Brown
9
L2
Black
10
L3
Black
11
GND
Yellow/Green
12
MOTOR 4
L1
Brown
13
L2
Black
14
L3
Black
15
GND
Yellow/Green
16+pe
MULTi CABLES
Wire
Colour / EU
Pin
L1
1
1
L2
2
2
L3
3
3
GND
4
4
L1
5
5
L2
6
6
L3
7
7
GND
8
8
L1
9
9
L2
10
10
L3
11
11
GND
12
12
L1
13
13
L2
14
14
L3
15
15
GND
16
16+pe
MAX. CABLE LENgTH in Meters
LiFTiNg CAPACiTY
PROLYFT HOiST
1,5mm2 cords
2,5mm2 cords
400V/50hz 230v/60hz
400V/50hz
230v/60hz
250KG
230
75
255
80
500 KG
100
40
110
45
1000KG
65
25
75
25
2000KG
65
25
75
25
The table above gives an indication of the maximum length of
cables between controller and hoist. Lengths are calculated in
accordance to EN 60204 and for the worst case situation.
If power cords with 1,5q/mm wires are connected to 2,5q/mm
wired cords the one with the smallest cross section determines the
maximum length.
The charts have been calculated with a maximum voltage
drop of 5%.