With an open end wrench adjust
the A. bolts (1/8 turn
at a time where needed and test
with dough. After satisfied,
tighten the locking bolts making
sure not to move the larger
adjustment bolts.
Upon activation, the
lower platen is slow
to come up and
down.
Filter encased in a black housing in
the back of the machine is dirty.
Replace filter.
---
Heater platens
overheating
If the relay (depending on the year of
the model) on the coil side are
receiving 12vdc indicates the
controller is functioning properly. On
the switching side of the relay, is
there 120 vac going to the heater in
question. If there is no voltage on
the to the switching side of the relay
to the heaters, the relay is not
working properly.
Replace relay If the controller's
heat-on LED is not lit indicating
the controller is working
properly.
92
8